THIS DISHWASHER IS PROGRAMMED WITH A SERVICE MODE TO AID THE TECHNICIAN IN TROUBLESHOOTING THE DISH- WASHER. EACH COMPONENT MAY BE CYCLED TO DETECT IF IT IS FUNCTIONING CORRECTLY. COMPONENTS ARE CYCLED BY PRESSING KEYPADS TO THE RIGHT OR LEFT OF THE START/RESET KEYPAD. DETERMINE WHICH TYPE OF CONTROL PANEL IS PRESENT (FLAT OR BOWED) AND THEN USE THE MATRIX BELOW TO DETERMINE HOW TO CYCLE EACH COMPONENT.

FLAT PANEL

BOWED PANEL

5L 4L 3L 2L 1L

START

1R 2R 3R 4R

RESET

Indicates Keypad Used Only on Some Models

5L

3L

2L

1L

4L

START

1R

2R

3R

4R

 

 

RESET

 

 

 

Indicates Keypad Used Only on Some Models

TO ENTER SERVICE MODE :

PRESS THE COOKWARE (POTS & PANS ON SOME MODELS) AND THE HEATED DRY KEYPAD SIMULTANEOUSLY FOR 3 SECONDS.

TO EXIT SERVICE MODE :

PRESS THE START/RESET KEYPAD AT ANYTIME TIME TO EXIT.

TRITON XL SERVICE MODE TEST MATRIX *

KEYPAD

 

 

DESCRIPTION

TIME in seconds**

 

 

 

 

CONTROL

 

PAD

 

TYPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keypads to the left of the Start/Reset keypad (Selections)

 

 

 

 

 

 

 

 

 

 

 

1L

 

 

FLAT

 

Activates Drain Pump

75

 

 

BOWED

Activates Detergent Module

 

 

 

 

 

2L

 

 

FLAT

Activates Detergent Module

60

 

 

BOWED

 

Activates Main Pump

 

 

 

 

 

 

3L

 

 

FLAT

 

Activates Main Pump

75

 

 

BOWED

Activates Heating Element

 

 

 

 

 

4L

 

 

FLAT

Activates Heating Element

300

 

 

BOWED

 

Activates Drain Pump

 

 

 

 

 

 

5L

 

 

FLAT

 

Activates Water Valve

50 or 71

 

 

BOWED

(Length of time is model dependent)

 

 

 

 

 

START/RESET

 

 

Used to EXIT Service Mode

Keypads to the right of the Start/Reset keypad (Enhancement/Extras)

 

 

 

 

 

 

Activates the following in order:

 

 

 

 

 

 

Status LEDs; Wash LEDs;

 

1R

 

FLAT

Start/Reset and Option LEDs;

3 seconds each cycle

 

 

 

 

BOWED

finally “888” will be shown

 

 

 

 

 

 

 

on the 3 digit display

 

 

 

 

 

 

 

(some models)

 

2R

 

FLAT

 

 

 

 

 

 

 

Opens Active Vent

 

 

 

 

BOWED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3R

 

 

FLAT

 

Closes Active Vent

 

 

 

 

 

 

 

BOWED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*NOTE : Service mode may be used for 30 minutes maximum. After 30 minutes the service mode will automatically turn off.

**NOTE : Component will be activated for indicated time. Component may be deactivated by pressing the same keypad that was pressed to activate the component.

– 25 –

Image 27
Contents Technical Service Guide Important Safety Notice Table of Contents Introduction Serial Number NomenclatureW 7 3 0 0 G 0 0 W W Model NumberProfile Models Control Panel FeaturesEnhancements GE Models StartExtraClean Sensor Selections Flashing Display Lights Door View Panel and Escutcheon Removed Component Locator ViewsBottom View Door ViewInside Door View Inside ViewSide View Escutcheon Keypad Assembly Dishwasher ComponentsDoor Components Detergent/Rinse Module Control ModuleStainless Steel Bowed Panel On Some Models Screws Door Interlock SwitchDrain System Bottom Door SealDishwasher Doesn’t Drain Circulation SystemNut Middle BearingSpray Arm Hub Calrod Heating Element Fill FunnelBottom View Turbidity Sensor Water Valve and Flood Switch Active Vent Flashing Display Lights Flat Panel Service ModeFactory Test Mode Washability Complaints Cycle Crystal Pans Bacteria Only Cycle Progression ChartControl Module Wiring DiagramParts List Body Parts Upper Rack Lower Rack Pumps and Filters Ref # Description Qty Conduit Main Clamp Hose Review For The Period GE Will Replace WarrantySecond Year