Greenheck Fan APEX-200 warranty Cleaning Energy Recovery Wheel Segments

Page 23

Routine Maintenance

CLEANING ENERGY RECOVERY WHEEL SEGMENTS

If the wheel appears excessively dirty, it should be cleaned to ensure maximum operating efficiency. Only excessive buildup of foreign material needs to be removed. DISCOLORATION AND STAINING OF ENERGY RECOVERY WHEEL DOES NOT AFFECT ITS PERFORMANCE.

Thoroughly spray wheel matrix with household cleaner such as Fantasticor equivalent. Gently rinse with warm water and using a soft brush remove any heavier accumulation. A detergent/water solution can also be used. Avoid aggressive organic solvents, such as acetone. The energy recovery wheel segments can be soaked in the above solution overnight for stubborn dirt or accumulation.

After cleaning is complete, shake the excess water from the wheel or segments. Dry wheel or segments before placing them back into the cassette. Place wheel or segments back into cassette by reversing removal procedures.

**DO NOT CLEAN ENERGY RECOVERY WHEEL SEGMENTS WITH WATER IN EXCESS OF 140°F

**DO NOT DRY ENERGY RECOVERY WHEEL SEGMENTS IN AIR IN EXCESS OF 140°F.

Energy Recovery Wheel Belt

Inspect belts each time filters are replaced. Belts that look chewed up or are leaving belt dust near the motor pulley may indicate a problem with the wheel. Be sure to inspect wheel for smooth and unrestricted rotation. If a belt requires replacement, contact the local Greenheck representative. Instructions for replacement will ship with the new belt.

FIGURE 30: Wheel belt & pulley

Energy Recovery Wheel Bearings

In the unlikely event that a wheel bearing fails, access is available through the access door above the exhaust blower discharge. Remove the plate shown in Figure 31 to access bearing.

FIGURE 31: Wheel bearing access

23®

Image 23
Contents INSTALLATION, OPERATION, & Maintenance Manual Storage Table of ContentsLifting InstallationBasic Unit Operation Roof Curb Mounting Unit Weights dry weightsRecommended Roof Openings Dampers Rail MountingWeatherhoods Typical Control Center Components Electrical ConnectionsDimensional Data / Access Door Descriptions Service Clearances / Access LocationsDirect Expansion DX Coils Coil Application RecommendationsWater Coils Variable Frequency Drive for Fans E7 Series by Yaskawa See page 13 for VFD on energy recovery wheelDrain Pan Traps Frost Control Application/Operation Testing refer to FigureTesting Modulating the Wheel Optional Accessories Remote Control Panel Special Tools Required Unit Start-UpPre-Start Check List Fan Performance Modifications Supply Fan Plenum TypeExhaust Fans Forward Curved Type Fan RPM Belt Drive InstallationFan Belt Drives Direction of Fan Wheel RotationVibration Energy Recovery WheelFan Belts Routine MaintenanceLubrication Bearings MotorsWheel & Fasteners Door Seal Maintenance External Filter MaintenanceInternal Filter Maintenance Winterizing Coils Coil MaintenanceAccessing Energy Recovery Wheel Cleaning Energy Recovery Wheel Segments Model Apex Parts ListWinter Operation Sequence of OperationBasic Unit Summer OperationTest and Balance Report Troubleshooting AirflowSymptom Possible Cause Corrective Action TroubleshootingGreenheck

APEX-200 specifications

The Greenheck Fan APEX-200 is a cutting-edge ventilation solution designed to meet the demands of modern commercial and industrial applications. Engineered with the latest technologies and featuring advanced design characteristics, the APEX-200 stands out for its efficiency, durability, and performance.

One of the prominent features of the APEX-200 is its energy-efficient operation. The unit is equipped with high-efficiency motors that not only reduce energy consumption but also provide optimal airflow, making it an ideal choice for organizations looking to lower their operational costs while maintaining superior performance. The APEX-200’s ability to operate at low sound levels adds to its appeal, allowing it to be installed in noise-sensitive environments without disturbing occupants.

The APEX-200 incorporates Greenheck's patented Aerodynamic Technology, which enhances airflow and minimizes turbulence. This technology ensures that the fan operates smoothly and efficiently, contributing to the overall effectiveness of the ventilation system. The innovative design of the fan blade and housing also plays a crucial role in maximizing performance while minimizing energy loss.

Durability is a key characteristic of the APEX-200. Constructed from high-quality materials, this fan is designed to withstand the rigors of demanding environments. The unit is also built to resist corrosion, ensuring longevity and reducing maintenance needs. This durability makes the APEX-200 suitable for a variety of applications, including manufacturing facilities, warehouses, and commercial kitchens.

Another significant aspect of the APEX-200 is its versatility. The fan is available in various sizes and configurations, allowing it to be tailored to specific project requirements. This flexibility makes it suitable for different airflow and pressure needs, ensuring optimal performance in diverse settings.

The APEX-200 also features advanced controls and monitoring capabilities. These systems can be integrated with building management systems to provide real-time data and insights into operational performance. Such features enhance user convenience and help facility managers optimize energy usage.

In conclusion, the Greenheck Fan APEX-200 is a sophisticated, reliable, and efficient solution for modern ventilation requirements. Its advanced technologies, high-efficiency operation, and durable construction make it an excellent choice for a wide range of applications, ensuring that it not only meets but exceeds the expectations of users in various industries.