Fisher & Paykel 590241 LCD Norm Fast Deli Rinse Hardware Output, Fast Test Cycle Level Three

Page 18

LCD Norm

Fast

Deli

Rinse

Hardware Output

-------------------------------------------------------------------------------------------

bL

Off

Off

Off

On

Backlight

Er

Off

Off

On

Off

Element Relay (turns off after 5 seconds)

Ld

Off

Off

On

On

Lid Motors (will run for 10 seconds)

dd

Off

On

Off

Off

Detergent Diverter Valve

FU

Off

On

Off

On

Fill Water Valve

P1

Off

On

On

Off

Motor Wash direction 2300-2850rpm (will not run if the tub is open)

P2

Off

On

On

On

Motor Drain direction 4200 rpm (times out after 255 seconds.)

rd

On

Off

Off

Off

Rinse Aid Dispenser (dispenses according to current user setting)

dF

On

Off

Off

On

Drying fan

LE

On

Off

On

Off

Rinse Aid and Salt Tank LEDs

C1

On

Off

On

On

Water Softener Diverter Valve

C2

On

On

Off

Off

Water Softener Brine Pump

C3

On

On

Off

On

Water Softener Brine Valve

°C

On

On

On

Off

Displays current water temperature.

°E

On

On

On

On

Displays controller rail voltage

(C3 is used in the factory to empty the water softener before the product is packed.)

Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED on integrated badge) indicates the tub position. On = closed, off = open.

Press POWER to skip hardware diagnostics and exit mode.

5.1.3Fast Test Cycle – Level Three

WARNING : Only run this cycle if connected to the water supply.

This level runs an 8-minute fast test cycle.

Flat door and Integrated will show the following LED’s on secondary display panel.

Pre Finished

Integrated and Flat Door Models

Will show the following LED’s on secondary

display panel

Press POWER to skip Fast Test Cycle and advance to the next level. Press START/PAUSE to enter Fast Test cycle.

18

Image 18
Contents F9 Diagnostic Manual DD60 BrandDD605/DS605 DD90Contents Fault Finding Procedure Controller Types F9 Fault CodeDisplay Secondary Panel Power Supply / Controller Fault Part Number MarketDevice Connector Pin Description Checking Specific ComponentsNZ/AU/EU/UK Component Checking Procedure Number ProcedureCheck the lid actuators Page Page Page Page Page Page Diagnostics Pre Finished Integrated and Flat Door Models F9 fault codeHardware Output Test Mode Level Two Pre Finished Integrated and Flat Door ModelsLCD Norm Fast Deli Rinse Hardware Output Fast Test Cycle Level ThreeContinuous Cycle Test Mode Level Four Wiring Diagram