Check the Water Softener:

If fitted, check the water softener coils, these can be checked at harness P202

Remove the water softener harness from the controller, and using a multimeter check the resistance between pins 1 & 2 for the softener bypass coil - take care not to spread the pins with the meter probes.

The following resistances should apply: 65 Ohms (+/- 10 Ohms)

Check the resistance between pin 3 & 4 for the brine pump,

The following resistances should apply: 65 Ohms (+/- 10 Ohms)

If shorted replace the coil, but continue to check the other components.

Or, the coils can be checked with a multimeter at the water softener itself.

12

Image 12
Contents F9 Diagnostic Manual Brand DD605/DS605DD60 DD90Contents Fault Finding Procedure F9 Fault Code Display Secondary Panel Power Supply / Controller FaultController Types Part Number MarketDevice Connector Pin Description Checking Specific ComponentsNZ/AU/EU/UK Component Checking Procedure Number ProcedureCheck the lid actuators Page Page Page Page Page Page Diagnostics Pre Finished Integrated and Flat Door Models F9 fault codeHardware Output Test Mode Level Two Pre Finished Integrated and Flat Door ModelsLCD Norm Fast Deli Rinse Hardware Output Fast Test Cycle Level ThreeContinuous Cycle Test Mode Level Four Wiring Diagram