Motor phases

P201

1 & 2

8.0 +/- 5 Ohms (per winding),

 

 

 

16 ohms phase to phase from the controller

 

 

 

connector

 

 

 

 

Dropper resistor

P101

4 & 5

NZ/AU/EU/UK

 

 

 

98 Ohms +/- 7 Ohms

 

 

 

US/CA

 

 

 

24 Ohms +/- 3 Ohms

 

 

 

 

Element

P101

6

NZ/AU/EU/UK

 

and

to

DD605/DD60 - 50 ohm +/- 4 Ohms

 

Power Plug

Neutral

DD90 - 38 ohm +/- 3 Ohms

 

 

Pin

US/CA

 

 

 

 

 

 

DD605/DD24 - 24 ohm +/- 3 Ohms

 

 

 

DD36 - 19 ohm +/- 2 Ohms

 

 

 

 

Note: DD90 & DD36 Heater track are in parallel, if one heater track fails, resistance will double.

(230V - 76 ohm : 120V - 38 ohm)

NOTE: Pins are counted right to left on connectors P101, P205, P201, P303, P302.

Connectors P202, 203, 204 – pin 1 is at the bottom of the connector.

7

Image 7
Contents F9 Diagnostic Manual DD90 BrandDD605/DS605 DD60Contents Fault Finding Procedure Part Number Market F9 Fault CodeDisplay Secondary Panel Power Supply / Controller Fault Controller TypesChecking Specific Components Device Connector Pin DescriptionNZ/AU/EU/UK Number Procedure Component Checking ProcedureCheck the lid actuators Page Page Page Page Page Page Pre Finished Integrated and Flat Door Models F9 fault code DiagnosticsPre Finished Integrated and Flat Door Models Hardware Output Test Mode Level TwoFast Test Cycle Level Three LCD Norm Fast Deli Rinse Hardware OutputContinuous Cycle Test Mode Level Four Wiring Diagram