Chicago Electric 66182 operating instructions Extension Cords, See 3-Prong Plug and Outlet

Page 6

electric shock.

(See 3-Prong Plug and Outlet.)

2.The grounding prong in the plug is connected through the green wire in- side the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal.

(See 3-Prong Plug and Outlet.)

3.The tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the preceding illustration.

(See 3-Prong Plug and Outlet.)

Extension Cords

1.Grounded tools require a three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge Extension Cord. Using exten- sion cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and pos- sible tool damage.

(See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the Cord. For example, a 14 gauge Cord can carry a higher current than a 16 gauge Cord. (See Table A.)

5.If you are using one Extension Cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum Cord size. (See Table A.)

6.If you are using an Extension Cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure the Extension Cord is properly wired and in good electrical condition. Always replace a damaged Extension Cord or have it repaired by a qualified electrician before using it.

8.Protect the Extension Cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

EXTENSION CORD

 

LENGTH

 

AMPERES

 

 

25’

50’

75’

100’

150’

(at full load)

 

 

 

 

 

 

 

 

 

 

 

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

4.When using more than one Exten- sion Cord to make up the total length, make sure each Cord contains at least the minimum wire size required.

(See Table A.)

SKU 66182

For technical questions, please call 1-800-444-3353.

Page 6

Image 6
Contents Heavy Duty HOT Knife General Safety Warnings Save This ManualMatching outlets will reduce risk of electric shock Specific Safety Warnings Grounding Grounded Tools Tools with Three Prong PlugsExtension Cords See 3-Prong Plug and OutletSpecifications SymbologyProduct Features UnpackingWork Area and Workpiece Set Up Maintenance Servicing TroubleshootingParts List & Assembly Diagram Description QtyLimited 90 DAY Warranty Please Read the Following Carefully