Cleveland Range KGT-12-T, KGT-6-T Reservoir Fill Procedures, Hands and Body Clear of Discharge

Page 20

RESERVOIR FILL

PROCEDURES

WARNING: IMPROPER REFILLING OF

KETTLE JACKET WILL RESULT IN IRREVERSIBLE DAMAGE TO UNIT.

The kettle's water level must be maintained at the proper level. Under normal operating conditions, the sealed water reservoir should never require the addition of water.

If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically low level. The low water protection control has automatically shut off the gas burner. The following procedure must be completed before further use:

C. Fill unit via Street Elbow

B.

Attach Street

Elbow

A.*

Remove

Pressure

Relief

Valve

*Important- Pull ring on Pressure Relief Valve prior to removal to insure vessel is not pressurized.

Pressure Relief Valve/Gauge Assembly Drawing

DANGER: PRESSURE RELIEF VALVE WILL EXHAUST HIGH TEMPERATURE STEAM. CONTACT WITH SKIN COULD RESULT IN SERIOUS BURNS. KEEP FACE,

HANDS AND BODY CLEAR OF DISCHARGE.

 

150

200

 

100

250

 

 

20

 

50

30

 

10

40

300

 

 

 

0

 

50

 

I

 

 

R

 

 

350

A

 

 

T

 

 

 

N

 

60

 

E

 

 

 

V

 

 

 

psi 400

kPa

1.Ensure kettle is at room temperature and pressure gauge showing zero or less pressure.

2.Shut off power to the kettle at the fused disconnect switch.

DANGER: WORKING ON MACHINES

WITH POWER COULD RESULT IN

SEVERE ELECTRICAL SHOCK.

NOTE: Have a qualified service technician repair the leakage problem and add water to the unit. Ensure that the red "low water" light is on when the kettle is upright. On tilting kettles, it is normal for the red light to come on when the kettle is in a tilted position.

DISTILLED WATER REQUIREMENTS

 

When red “Low

Kettle

Water Light” comes

Capacity

on, add distilled water

 

 

6 gallon

70 ounces

12 gallon

120 ounces

 

 

3.Pull Pressure Relief Valve (A) open to insure vessel is not pressurized.

4.Remove Pressure Relief Valve (A).

5.Replace Pressure Relief Valve (A) with Street Elbow (B).

6.Add distilled water (C) through the Street Elbow (B), using a funnel if necessary. Fill the unit to the high

level mark on the Sight Glass.

Sight

Glass

7.Apply a thread sealant (i.e. Teflon tape) to the Pressure Relief Valve's (A) thread and replace.

8.Restore power to unit at the fused disconnect switch.

9.The kettle must now be vented. (Refer to the

KETTLE VENTING INSTRUCTIONS).

Image 20
Contents Operators Manual For the User Retain this Manual for Your ReferenceInstallation Installation Checks CleaningElectrical VentilationOperating Instructions Item # Description FunctionOperating the Kettle Approximate Boiling TimesCleaning Instructions Care and CleaningCleaning Instructions Marine LockStainless Steel Equipment Care and Cleaning Warranty Service PartsFaucet Assembly Console Components Used after JuneConsole Components Trunnion Assembly Trunnion AssemblySwitches & Indicators Switches & Indicators Main Components Piping Assembly Piping Assembly Maintenance Inspection and Maintenance Check ListCalibrating Procedure Pressure Relief Valve Periodic Testing ProcedureReservoir Fill Procedures Hands and Body Clear of DischargeKettle Jacket Cleanout and Passivation Procedures Mixing / Filling ProcedureKettle Venting Instructions Vacuum Leak Test ProcedureRepairing Leaks in Steam Jacketed Kettle Fittings Wiring Diagram Item # DescriptionOperating Sequences Solid State Control SequenceMarine Lock Testing Procedure GAS Valve Replacement KIT Item # KE55240-7