Amana MVH230*, MVH330*, MVH130* installation instructions Recirculating Exhaust Non-Vented/Ductless

Page 5

5.Carefully pull out blower unit. Wires extend far enough to allow for blower adjustments.

6.Turn blower unit end-over-end. Roll blower unit so fan blade openings are facing out back of microwave oven. Blower unit exhaust openings should match exhaust openings on rear of microwave oven. Wires should be routed in front of motor fan.

7.Guide wires into duct while placing blower unit back into opening. Secure blower motor with screw removed in step 4.

9.Fit exhaust adaptor into house duct. Be sure damper hinge is on top and damper swings free into wall outlet.

10.Remove paper from sticky side of 28 inch foam tape strip. Press sticky side onto front edge of exhaust adaptor. (Do not stretch foam tape).

11.Proceed to "Preparing Top Cabinet".

Recirculating Exhaust (Non-Vented/Ductless)

Exhaust adaptor with damper is not needed for recirculating models. Save exhaust adaptor with damper for possible future use. Charcoal filter kit must be used. Contact dealer to purchase charcoal filter kit.

1.Slide exhaust adaptor to one side, squeeze sides and remove. Save damper and exhaust adaptor.

2.Remove and save 3 screws that hold blower plate to microwave oven.

3.Lift off blower plate.

Caution

To avoid product failure, do not pull, stretch, or pinch blower wiring.

8.Replace blower plate using 3 screws.

4. Remove and save the screw that holds blower motor to microwave.

5

Image 5
Contents Page Electrical Requirements Mounting SpaceMaterials Needed Not Supplied Accessories Available for Purchase from DealerMaterials Needed Supplied Hood Exhaust DuctPreparing Microwave Exhaust Duct Removing Mounting PlateRecirculating Exhaust Non-Vented/Ductless Preparing Top Cabinet Mounting Bracket Assembly to WallPreparing Rear Wall Cutout Opening for Outside Back Exhaust Mounting Microwave Oven Installation ChecklistPage Page Page Part No. C8935507