Amana MVH330* Materials Needed Not Supplied, Materials Needed Supplied, Hood Exhaust Duct

Page 3

Materials Needed (Not Supplied)

Phillips screwdriver

Pencil

Ruler or tape measure and straight edge

Protective gloves

Carpenter square (optional)

Tin snips (in some applications)

Electric drill with 1/2, 3/16, and 5/8 inch drill bits

Hammer

Stud finder (optional)

Filler blocks, if needed for top cabinet spacing

Saw (jig or keyhole)

Charcoal filter kit (for inside recirculating installation)

Filler panel kit (if space between cabinets is greater than 30 inches)

Materials Needed (Supplied)

Installation hardware is contained in packet shipped with microwave oven. Verify all parts listed below are included in packet.

14

Hood Exhaust Duct

Outside ventilation requires hood exhaust duct. Use only metal duct. Read the following carefully.

Exhaust Connection: Hood exhaust has been designed to mate with standard 3 1/4 inch x 10 inch rectangular duct. If round duct is required, rectangular-to-round transition adaptor must be used. Do not use less than 6 inch diameter duct.

Rear Exhaust: If rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs.

Maximum Duct Length: Total duct length of 3 1/4 inch x 10 inch rectangular or 6 inch diameter round duct should not exceed 140 equivalent feet for satisfactory air movement.

Elbows, Transitions, Wall and Roof Caps, Etc.

Elbows, transitions, wall and roof caps, etc., create additional resistance to airflow and are equivalent to a section of straight duct. When calculating total duct length, add equivalent lengths of all transitions and adaptors, plus length of all straight duct sections. Chart below shows approximate feet of equivalent length of some typical ducts.

2

3

5

6

Duct

Equivalent Length

Rectangular-to-Round Transition

5 FT.

Adaptor

 

Wall Cap

40 FT

90° Elbow

10 FT.

45° Elbow

5 FT.

90° Elbow

25 FT.

45° Elbow

5 FT.

Roof Cap

24 FT.

#

Description

Quantity

1

Wood screws 1/4 x 2 inches

1

2

Toggle Bolts, 3/16 inch

2

3

Machine screws 1/4 x2 3/4

4

4

Washers

4

5

Nylon grommet

2

 

(for metal cabinets)

 

6

Foam Tape 28 inch piece

2

Accessories Available for Purchase from Dealer

Charcoal filter kit: Charcoal filter kit is needed for recirculating exhaust installation.

Filler panel kit: If space between cabinets is greater than 30 inches, filler panel kit may be used to fill in gap between microwave oven and cabinets.

*If rectangular-to-round transition adaptor is used, bottom corners of damper will have to be cut to fit, using tin snips, in order to allow free movement of damper.

3

Image 3
Contents Page Electrical Requirements Mounting SpaceHood Exhaust Duct Accessories Available for Purchase from DealerMaterials Needed Not Supplied Materials Needed SuppliedPreparing Microwave Exhaust Duct Removing Mounting PlateRecirculating Exhaust Non-Vented/Ductless Preparing Top Cabinet Mounting Bracket Assembly to WallPreparing Rear Wall Cutout Opening for Outside Back Exhaust Mounting Microwave Oven Installation ChecklistPage Page Page Part No. C8935507