Carrier HFC-134A installation instructions Control Center Components

Page 6

6

a23-

 

 

1554

21

1

 

 

19

18

17

16

1Input Inductor Assembly

2Capacitor Bank Assembly

3Pre-Charge Resistor Assembly

4AC Contactor (3)

5Power Module Assembly

6Terminal Block, 10-Position (2)

7Power Module Nameplate

8Fuse Black, 30A, 600V, Class CC

9Fuse, Class CC, 600V, 15A (2)

10Fuse, Class CC, 600V, 5A (1)

11Fuse, Class CC, 600V, 20A (3)

11

2813

16

8

14

3

 

 

 

12

15

 

10

20

9

8

5

6

 

4

7

6

12Fuse, Class CC, 600V, 1A (3)

13Transformer, 3kVA

14Line Sync PC Board Assembly

15Line Sync Board Cover

16Fan, 115V (3)

17Circuit Breaker, 600V, 15A

18Circuit Breaker, 600V

19Lug, Ground, 2-600 MCM

20Communications Interface Board

21Input Power Wiring Panel

Fig. 6 — Control Center Components

Image 6
Contents Installation Instructions Contents Model Number Identification Typical 23XRV Components A23-155051A23-1551 A23-1553Control Center Components A23-1555 A23-155623XRV Dimensions Nozzle-In-Head Waterbox A23-155723XRV Component Weights TR Compressor 23XRV Dimensions Marine Waterbox23XRV Compressor Weights 23XRV Waterbox Nozzle Sizes23XRV Heat Exchanger Data 23XRV Additional Data for Cooler Marine Waterboxes23XRV Waterbox Cover Weights English lb 23XRV Waterbox Cover Weights SI kg23XRV Additional Data for Condenser Marine Waterboxes Electrical Cable Routing Top View Cooler/Discharge Pipe Assembly Removal A23-1635 A23-1563A23-1564 A23-1565 A23-1567A23-1570 A23-1571 Cables A23-1561Control Panel Inputs A23-1568 A23-1569Compressor Fastener Identification A23-1572Oil Concentrator Removal A23-1573Oil Reclaim Piping Motor Terminal Box A23-1576A23-1578 A23-1579COUPLINGSA23-1534 A23-46A19-1109 A19-1110 A23-1537 A23-1580A23-1538 A23-1581A23-1539 A23-1540A23-1541 A23-1543Rated DRY Weight and Refrigerant Capacity A23-1634A23-1544 A23-1545Pumpout Unit Relief Valve ArrangementsRelief Valve Locations Close the door to the control centerTypical Field Wiring Schematic A23-1585A23-1586 Typical Field Wiring Schematic Lug Capacity A23-1587PIC III Control Component Layout A23-1584Page 23XRV Controls Schematic A23-1588A23-1589 A23-1591 A23-1590 A23-1592CCN Communication Wiring For Multiple Chillers Typical A23-159323XRV with Unit-Mounted VFD/Control Center A23-1594Cable Manufacturers A23-1595A23-1596 Install Field Insulation and Lagging Insulator CodesLead/Lag Control Wiring A23-1597A23-1598 23XRV Insulation Area A23-1599Page Page Copyright 2006 Carrier Corporation Installation START-UP Request Checklist Testing YES/NO Date to be Completed

HFC-134A specifications

Carrier HFC-134A, also known as tetrafluoroethane, is a hydrofluorocarbon (HFC) refrigerant widely used in a variety of cooling and heating applications. It is recognized for its role in refrigeration and air conditioning systems, making it a crucial component in many modern HVAC units. One of the key features of HFC-134A is its zero ozone depletion potential, which makes it an environmentally friendly alternative to older refrigerants like CFCs and HCFCs.

The characteristics of HFC-134A include its stability, non-corrosiveness, and effectiveness at low temperatures. These properties allow it to perform efficiently in both residential and commercial refrigeration systems. The refrigerant operates within a temperature range that is ideal for many applications, including food preservation and air conditioning. HFC-134A's thermodynamic properties enable it to absorb and release heat effectively, making it suitable for both vapor-compression and absorption refrigeration cycles.

From a technological perspective, the use of HFC-134A aligned with the transition to more sustainable refrigerants. As global environmental regulations have tightened, manufacturers have shifted towards refrigerants with lower global warming potential (GWP). HFC-134A has a GWP of approximately 1,430, which is lower than many of its predecessors but still higher than some newer alternatives. This aspect drives ongoing research and development in the industry, aiming to create even more environmentally sound refrigerants.

Carrier HFC-134A is compatible with various lubricants and can be integrated into systems designed for other refrigerants with minimal modifications. This flexibility allows for a smoother transition within existing installations as businesses and homeowners upgrade their HVAC systems to comply with environmental regulations.

In summary, Carrier HFC-134A plays a significant role in modern refrigeration and air conditioning technology. Its main features, including zero ozone depletion potential, stability, and efficiency, contribute to its widespread use in various applications. As the industry continues to evolve, the focus on reducing the environmental impact of refrigerants will undoubtedly influence the future direction of HFC-134A usage and the development of new alternatives.