Kuppersbusch USA GKS 11742.0-35 F-UL manual Electricalconnection

Page 10

INSTALLATION

8) ELECTRICALCONNECTION

The electrical connections of the appliance must be carried out in compliance with the provisionsandstandardsinforce.

Before connecting the appliance, check that:

- the electrical capacity of the mains supply and current sockets suit the maximum power rating of the appliance (consult the data label applied to the underside of the hot plate).

- The socket or system has an efficient earth connection in compliance with the provisions and standards in force. The manufacturer declines all responsibility for failing to comply with these provisions.

When the appliance is connected to the electricitymainbyasocket:

- fit a standard plug suited to the load indicated on the data label to the cable.

- Fit the wires following figure 8, taking care of respecting the following correspondences:

LetterL(live) = wire; LetterN(neutral) = wire;

earthsymbol = greenoryellow-greenwire.

-Never use reductions, adapters of shunts for connection since these could create false contacts and lead to dangerous overheating.

-Theoutletmustbeaccessibleafterthebuilt-in.

When the appliance is connected straight to the electricitymain:

- install an omnipolar circuit-breaker between the appliance and the electricity main. This circuit- breaker should be sized, in compliance with current installation regulations.

- Remember that the earth wire must not be interrupted by the circuit-breaker.

- For optimum safety, the electrical connection may also be protected by a high sensitivity differential circuit- breaker.

You are strongly advised to fix the relative yellow- green earth wire to an efficient earthing system.

FIG.8

10

Image 10
Contents Model GKS 11742.0-35 F-UL Descriptionofhobs Model GKS 11742.0-35 F-ULSafeguardinstructions Safe Guard InstructionsUSE BurnersUSE Cleaning WorktopCleaning 4INSTALLINGTHEWORKTOP InstallationFixing the HOT Plate 7GASCONNECTION 6ROOMVENTILATIONNaturalGasandPropaneGas Electricalconnection Fixing the HOT Plate Adjustments ReducedrateadjustmentReplacing the Injectors ConversionsArrangement of the Burners Greasingthetapsseefig.17 ServicingReplacing Components Liquid. TheuseoftheflameisprohibitedTechnicaldataonthedatalabel 4BURNERS110Technicalassistanceandspares Brand Model Series