ADJUSTMENTS

Always disconnect the appliance from the electricitymainbeforemakinganyadjustments. All seals must be replaced by the technician at theendofanyadjustmentsorregulations.

Our burners do not require primary air adjustment.

10) TAPS

“Reducedrate”adjustment

- Switch on the burner and turn the relative knob to the“Reducedrate”position(smallflamefig.1).

- Remove knob “M” (fig. 11) of the tap, which is simplypressedontoitsrod.

- Insert a small screwdriver “D” into hole “C” (fig. 11) and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the“Reducedrate”position.

Check that the flame does not go out when the knob is sharply switched from the “Full on” to the “Reduced rate” position.

It is understood that only burners operating with Natural Gas or Town gas should be subjected to the above mentioned adjustments. The screw must be fully locked when the burners operate with Propane HD-5 (turn clockwise).

FIG.11

12

Image 12
Contents Model GKS 11742.0-35 F-UL Descriptionofhobs Model GKS 11742.0-35 F-ULSafeguardinstructions Safe Guard InstructionsUSE BurnersUSE Cleaning WorktopCleaning Installation 4INSTALLINGTHEWORKTOPFixing the HOT Plate 6ROOMVENTILATION 7GASCONNECTIONNaturalGasandPropaneGas Electricalconnection Fixing the HOT Plate Adjustments ReducedrateadjustmentConversions Replacing the InjectorsArrangement of the Burners Servicing Replacing ComponentsGreasingthetapsseefig.17 Liquid. TheuseoftheflameisprohibitedTechnicaldataonthedatalabel 4BURNERS110Technicalassistanceandspares Brand Model Series