(3)CHECKOUT PROCEDURES FOR CIRCUIT BOARD The following symptoms indicate a defective circuit board.
(1)Check the input current. If the input current is more than 20A, check the magnetron and wiring. If the input current is less than 0.5 A, there is no input to the inverter.
(2)The start function fails to operate but the interlock switches, the door sensing and the relay check good.
(3)The unit with a normal relay continuously operates.
(4)The buzzer does not sound or continues to sound.
(5)Some segments of one or more digits do not light up, or they continue to light up, or segments light when they should not.
(6)Wrong figures appear.
(7)The figures of all digits flicker.
(8)Some of the indicators do no light up.
(9)The clock does not keep time properly.
NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON.