Liebherr 36 manual Cabinet Opening Dimensions 30 and 60 Models, Unit Venting

Page 14

Freestanding/Semi Built In Models

CS 1601, CS 1650, SBS 32S0

Cabinet Opening Dimensions - 30" and 60" Models

Electric outlet location

Water supply area.

Do not install the shut-off valve behind the appliance.

The appliance can be integrated into the kitchen units. To adapt the appliance to the height of the row of kitchen units, a suitable top cupboard can be fitted above the appliance.

Unit Venting

DO NOT restrict the air flow. An air flow of at least 2" (50mm) must be provided. The opening can either be directly over the appliance or on the back of the cabinet on top of the unit (see ventilation requirements).

The CS models can be installed in standard 24" deep cabinets. You will only have to make sure that the door swing clearance is enough. It is possible to push all CS models to the rear wall of the cabinet without modification.

When installing the appliance next to a wall, a distance on the hinge side of 1 27/64 inches (36 mm) minimum is required be- tween the appliance and the wall to allow for the door handle projection when the door is open.

Minimum Cabinet Opening Dimensions:

CS 1601, 1650

A.29-7/8" (759 mm)

B.23-3/16" (589 mm)

C.85" (2159 mm)

D.83-11/16" (2075 mm)*

SBS 32S0 (CS 1601 & CS 1650)

A.59-1/2" (1511 mm)

B.23-3/16" (589 mm)

C.85" (2159 mm)

D.83-11/16" (2075 mm)*

*Note:

The given cabinet opening height dimension includes 2" for top air vent.

If you choose to place the vent above the cabinet or in a soffit, you will need to adjust the height dimension accordingly.

5

Image 14
Contents Design Guide Freestanding / Semi Built In Models 30, 36Page Welcome Liebherrs Commitment to the EnvironmentIntroduction For Service and Parts in the U.S. Liebherr Service CenterFor Service and Parts in Canada Euro-Line Appliances Liebherr orContents Page General Remarks Safety WarningsTo the Installer III. IceMaker if equipped II. Electrical Requirements & SafetySafety Instructions and Warnings Safety Regulations IV. Area RequirementsModels Freestanding/Semi Built In Models30, 36 and 60 Models CS 16.., CS 2062, SBS 32S0 60 Models SBS 32S0 CS 1601 & CSUnit Dimensions Freestanding Models SBS 32S0 Cabinet Opening Dimensions 30 and 60 Models Unit VentingCabinet Opening Dimensions 36 Models 36 914 mm 24 610 mm 80-1/2 2045 mmVentilation Requirements CS 1601, CS 1650, SBS 32S0 Kitchen Cabinet AirflowVentilation Requirements CS Top Door Hinge Clearance CS 16.. SBS 32S0 Top Door Hinge Clearance CS Design Guide