Liebherr 36, 30 manual Ventilation Requirements CS 1601, CS 1650, SBS 32S0, Kitchen Cabinet Airflow

Page 16

Freestanding/Semi Built In Models

CS 1601, 1650 - SBS 32S0

Ventilation Requirements CS 1601, CS 1650, SBS 32S0

This type of cabinet must be carefully constructed using the correct dimensions and it must provide suitable ventilation to ensure proper appliance operation.

Kitchen Cabinet Airflow

1.The following ventilation dimensions must be observed:

There must be a ventilation space at least 31 in.² (200 cm²) at the airflow inlet (1) and at the airflow outlet (2). The 30" and 60" models are equipped with a rolling base, which is already providing you with the bottom airflow inlet require- ments.

The top ventilation space can be directed in one of the fol- lowing ways:

A)Directly over the appliance (2) with either an optional factory air vent or custom made one using the template sup- plied with the unit.

B)Above the cabinet and below the ceiling (3).

C)Through a vent installed in a soffit (4).

A

B

C

B - Side view

Cabinet

Refrigerator

The refrigerator is designed to allow proper air flow when the appliance is installed up against the wall.

A minimum space of 1 1/2" is required when a cabinet is built above.

7

Image 16
Contents Design Guide Freestanding / Semi Built In Models 30, 36Page Welcome Liebherrs Commitment to the EnvironmentFor Service and Parts in the U.S. Liebherr Service Center For Service and Parts in Canada Euro-Line AppliancesIntroduction Liebherr orContents Page To the Installer Safety WarningsGeneral Remarks Safety Instructions and Warnings II. Electrical Requirements & SafetyIII. IceMaker if equipped Safety Regulations IV. Area Requirements30, 36 and 60 Models CS 16.., CS 2062, SBS 32S0 Freestanding/Semi Built In ModelsModels 60 Models SBS 32S0 CS 1601 & CSUnit Dimensions Freestanding Models SBS 32S0 Cabinet Opening Dimensions 30 and 60 Models Unit VentingCabinet Opening Dimensions 36 Models 36 914 mm 24 610 mm 80-1/2 2045 mmVentilation Requirements CS 1601, CS 1650, SBS 32S0 Kitchen Cabinet AirflowVentilation Requirements CS Top Door Hinge Clearance CS 16.. SBS 32S0 Top Door Hinge Clearance CS Design Guide