Rangemaster RG60 manual Technical Data, Dimensions, Connections, Ratings

Page 15

8. Technical Data

DocNo.101-0001 - Technical data RG60 gas

The hob is an independent Class 3 built-in unit.

This hob is category II2H3+

It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.

INSTALLER: Please leave these instructions with the user.

DATA BADGE LOCATION: Base of the hob.

COUNTRY OF DESTINATION: GB/IE

Gas

 

Electric

 

 

 

Natural Gas

 

20mbar

220 – 240V 50Hz

 

 

 

 

Butane

 

29mbar

 

 

 

 

 

Propane

 

37mbar

 

 

 

 

 

(See appliance data badge for test pressures)

 

 

Dimensions

Overall height

Above worktop 50mm

 

Below worktop 50mm

 

 

 

 

Overall width

620mm;

see ‘Positioning of Cooker’

 

 

 

 

Overall depth

 

520mm

 

 

 

Space for fixing

See ‘Positioning of Cooker’

 

 

 

 

Minimum space above hotplate

 

650mm

 

 

 

 

Connections

Gas

Electric

 

 

Rp ½ at rear right-hand side

220 – 240V 50Hz

 

 

Ratings

 

Natural Gas

 

L.P. Gas

 

 

 

 

 

 

 

 

Hotplate

 

 

Injector

 

 

Injector

 

 

 

 

 

 

 

Large Burners

3.0kW

 

129

3.0kW (218g/h)

 

87

 

 

 

 

 

 

 

Medium Burners

1.75kW

 

101

1.75kW (124g/h)

 

66

 

 

 

 

 

 

 

Small Burner

1.0kW

 

77

1.0kW (73g/h)

 

50

 

 

 

 

 

 

 

Gas burner inputs based on Gross Calorific Value

13

Image 15
Contents RG60 Contents Before You Start Cleaning DocNo.021-0001 Overview RG60 gas Hob OverviewHob Care Essential information Cleaning Your HobCleaning Table Cleaning the hotplateHotplate ignition or hotplate burners faulty TroubleshootingRepublic of Ireland Provision of VentilationLocation of the Hob ConversionHood manufacturer’s instructions Installation satisfactorilyFixing the Hob Safety InformationPressure Testing Gas ConnectionThank you Electrical ConnectionsHotplate checks Customer CareAffix Label Tap AdjustmentConversion to LPG Gas InjectorsCircuit Diagram Ratings Technical DataDimensions ConnectionsWarranty/After Sales Service Page Page Page DocNo.000-0001 Back cover Rangemaster