Rangemaster RG60 manual Conversion to LPG Gas, Injectors, Tap Adjustment, Affix Label

Page 13

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

6. Conversion to LPG Gas

DocNo.071-0001 - LP gas conversion - BI hobs

Check in the ‘Technical Data’ section at the back of the

instructions that the cooker is convertible to the gas youFig.6-1 want to use.

This conversion must be performed by a suitably competent person, in accordance with these instructions and with the local supply company requirements.

Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to

prosecution.����������������������������������������

The conversion instructions must be used in conjunction with the rest of the appliance instruction, in particular for information on Standards, cooker positioning, connection, hose suitability, etc.

When servicing or replacing gas-carrying components, disconnect from the gas before starting, and check that the appliance is gas sound after completion.

Do not use reconditioned or unauthorised gas controls.

Disconnect from the electricity supply before commencing servicing.

Before electrical reconnection, check that the appliance is electrically safe.

Injectors

Remove burner caps and heads. Remove old jets. Fit the new jets (see Technical Data section at the back of the book for correct jets). Reassemble in reverse order.

Tap Adjustment

Disconnect from the electricity supply.

Pull off all the control knobs. Insert a suitable small flat screwdriver into the hole in the end of the control spindle, and turn the bypass screw on each control clockwise to the stop (Fig.6-1). Refit the control knob.

Affix Label

Stick the LP gas label over the natural gas part of the appliance data label.

Pressure Testing

Make sure that the appliance is gas sound; refer to ‘Pressure Testing’ earlier in the section.

Check the operation of all the burners.

11

Image 13
Contents RG60 Contents Before You Start Cleaning DocNo.021-0001 Overview RG60 gas Hob OverviewHob Care Cleaning Table Cleaning Your HobCleaning the hotplate Essential informationHotplate ignition or hotplate burners faulty TroubleshootingLocation of the Hob Provision of VentilationConversion Republic of IrelandHood manufacturer’s instructions Installation satisfactorilyPressure Testing Safety InformationGas Connection Fixing the HobHotplate checks Electrical ConnectionsCustomer Care Thank youConversion to LPG Gas Tap AdjustmentInjectors Affix LabelCircuit Diagram Dimensions Technical DataConnections RatingsWarranty/After Sales Service Page Page Page DocNo.000-0001 Back cover Rangemaster