WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
6. Conversion to LPG Gas
Check in the ‘Technical Data’ section at the back of the
instructions that the cooker is convertible to the gas youFig.6-1 want to use.
This conversion must be performed by a suitably competent person, in accordance with these instructions and with the local supply company requirements.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to
prosecution.����������������������������������������
The conversion instructions must be used in conjunction with the rest of the appliance instruction, in particular for information on Standards, cooker positioning, connection, hose suitability, etc.
When servicing or replacing
Do not use reconditioned or unauthorised gas controls.
Disconnect from the electricity supply before commencing servicing.
Before electrical reconnection, check that the appliance is electrically safe.
Injectors
Remove burner caps and heads. Remove old jets. Fit the new jets (see Technical Data section at the back of the book for correct jets). Reassemble in reverse order.
Tap Adjustment
Disconnect from the electricity supply.
Pull off all the control knobs. Insert a suitable small flat screwdriver into the hole in the end of the control spindle, and turn the bypass screw on each control clockwise to the stop
Affix Label
Stick the LP gas label over the natural gas part of the appliance data label.
Pressure Testing
Make sure that the appliance is gas sound; refer to ‘Pressure Testing’ earlier in the section.
Check the operation of all the burners.
11