Rangemaster RGG77 manual Technical Data, Dimensions, Connections, Ratings

Page 16

8. Technical Data

DocNo.101-0004 - Technical data RGG77 gas

The hob is an independent Class 3 built-in unit.

This hob is category II2H3+

It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.

INSTALLER: Please leave these instructions with the user.

DATA BADGE LOCATION: Base of the hob.

COUNTRY OF DESTINATION: GB/IE

Gas

 

Electric

 

 

 

Natural Gas

 

20mbar

220 – 240V 50Hz

 

 

 

 

Butane

 

29mbar

 

 

 

 

 

Propane

 

37mbar

 

 

 

 

 

(See appliance data badge for test pressures)

 

 

Dimensions

Overall height

Overall 100mm;

 

Above worktop 50mm;

(120mm including gas connection)

 

Below worktop 50mm

 

 

 

 

 

Overall width

770mm; see ‘Positioning of Cooker’

 

 

 

 

Overall depth

510mm

 

 

 

 

Space for fixing

See ‘Positioning of Cooker’

 

 

 

 

Minimum space above hotplate

650mm

 

 

 

 

 

Connections

Gas

Electric

 

 

Rp ½ at rear right-hand side

220 – 240V 50Hz

 

 

Ratings

 

Natural Gas

 

L.P. Gas

 

 

 

 

 

 

 

 

Hotplate

 

 

Injector

 

 

Injector

 

 

 

 

 

 

 

Triple ring burner

3.5kW

 

141

3.5kW (255g/h)

 

94

 

 

 

 

 

 

 

Large Burners

3.0kW

 

129

3.0kW (218g/h)

 

87

 

 

 

 

 

 

 

Medium Burners

1.75kW

 

101

1.75kW (124g/h)

 

66

 

 

 

 

 

 

 

Small Burner

1.0kW

 

77

1.0kW (73g/h)

 

50

 

 

 

 

 

 

 

Gas burner inputs based on Gross Calorific Value

14

Image 16
Contents RGG77 Contents Before You Start Cleaning Hob Overview DocNo.021-0004 Overview RGG77 gasTriple Ring burner Hob CareEssential information Cleaning Your HobHotplate Burners Cleaning Table Cleaning the hotplateTroubleshooting Hotplate ignition or hotplate burners faultyProvision of Ventilation Location of the HobConversion Republic of IrelandPositioning the Hob Checking the PartsYou will also need the following tools Pressure Testing Safety InformationConversion to LP Gas Connection Electrical Connections Hotplate Customer Care Thank youTap Adjustment Conversion to LPG GasInjectors Affix LabelCircuit Diagram Technical Data DimensionsConnections RatingsWarranty/After Sales Service Page Page DocNo.000-0001 Back cover Rangemaster