hussman RGSSFP manual Stocking, Case Cleaning, Ballast Location, User Information, Important Steps

Page 6

specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration ther- mostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs the length of the front of the case. Refer to diagram on page 5.

User Information

STOCKING

Improper temperature and lighting will cause serious prod- uct loss. Discoloration, dehydration and spoilage can be controlled with proper use of the equipment and handling of product. Product temperature should always be main- tained at a constant and proper temperature.This means that from the time the product is received, through stor- age, preparation and display, the temperature of the prod- uct must be controlled to maximize life of the product. Hussmann cases were not designed to “heat up” or “cool down” product—but rather to maintain an item’s proper temperature for maximum shelf life. To achieve the pro- tection required always:

1.Minimize processing time to avoid damaging tem- perature rise to the product. Product should be at proper temperature.

2.Keep the air in and around the case area free of foreign gasses and fumes or food will rapidly dete- riorate.

3.Maintain the display merchandisers temperature controls as outlined in the refrigerator section of this manual.

4.Do not place any product into these refrigerators until all controls have been adjusted and they are operating at the proper temperature.Allow mer- chandiser to operate a minimum of 6 hours before stocking with any product.

5.When stocking, never allow the product to extend beyond the recommended load limit. Air dis- charge and return air flue must be unob- structed at all times to provide proper refrig- eration.

6.There are vents located at the base of the front of the glass, just above the front rail.These vents supply a continuous, gentle flow of air across the front glass which inhibits condensation. Do not place any signs or other restrictive objects on the front of the refrigerator that will block these vents.

7.Avoid the use of supplemental flood or spot lighting. Display light intensity has been designed for maxi-

IGFP-RGSSFP-0008

mum visibility and product life at the factory.The use of higher output fluorescent lamps (H.O. andV.H.O.), will shorten the shelf life of the product.

IMPORTANT STEPS

1.Do not set temperature too cold, as this causes

product dehydration. ProductTemperature:

33° –35°!

Set thermostat to cut in at 28° discharge air. Meat holding box: 32° . Meat prep room: 55° . Meat bloom box: 36° .

Process the meat to enter case at 40° or below. Product deterioration is very rapid above 40° .

2.Temperature control in service sections should be by means of aT-Stat and Suction Stop Solenoid at each case. Do not use EPR valves, Liquid Line Solenoids or electronic control devices of any kind, as these allow temperature swings causing dehydra- tion and excessive energy consumption.

3.Product should be worked and rotated on a regular basis, not to exceed a 4-hour period.

4.At night, turn off case lights and cover the product with a damp (not wet) cloth similar to cheese cloth (etc.).This should be washed out in the morning and kept in a walk-in box during the day—so that it is cool and moist when covering the product.

5.Discharge air temperature should be approximately 26° F, with between 150-200 FPM air velocity. Do not

display product directly within the air discharge.

CASE CLEANING

Long life and satisfactory performance of any equipment are dependent upon the care given to it.To insure long life, proper sanitation and minimum maintenance costs, the refrigerator should be thoroughly cleaned frequently. It is essential to establish and regulate cleaning procedures.This will minimize bacteria causing discoloration which leads to degraded product appearance and significantly short- ening product shelf life.

SHUT OFF FAN DURING CLEANING PROCESS. It can be unplugged within the case,or shut off case at the source. The interior bottom may be cleaned with any domestic soap or detergent based cleaners.

The use of hoses and sage machines to clean the inside of the cases is recommended and is an excellent way to clean the coil fins and hard to reach corners of the interior of the cases. Be sure to observe the warnings below when cleaning the case.

Sanitizing solutions will not harm the interior bottom, however, these solutions should always be used according to the manufacturer’s directions and should not contain

6

Image 6
Contents Rgssfp Apparent Loss or Damage This Booklet Contains Information on RgssfpShipping Damage Concealed Loss or DamageLeveling Joint TrimWaste Outlet and P-TRAP Access to TX Valves & Drain Lines Installing Condensate DrainControl Settings Refrigerant TypeWiring Color Code Stat LocationBallast Location Case CleaningStocking User InformationNON-GLARE Glass Cleaning Plexiglass & Acrylic CareReplacing Fluorescent Lamps Tips & TroubleshootingFor Prompt Service Evaporator FansSpecifications ElectricalcircuitsElectrical Schematics Rgssfpcase Wiringdiagram4CASE Rgssfpcase 6CASE8CASE 12CASE IGFP-RGSSFP-0008 Type of Refrigerator Typical Entering Air Temperature AppendicesAppendix D. Recommendations to user Limited Warranty Model Serial Number

RGSSFP specifications

The Hussman RGSSFP (Refrigerated Glass Self-Service Food Preservation) is an innovative refrigerated display case designed for retail environments such as supermarkets and convenience stores. It uniquely combines aesthetics with functionality, offering an ideal solution for showcasing perishable food items, ensuring freshness while enhancing visual appeal.

One of the main features of the RGSSFP is its advanced temperature control system. This system maintains optimal temperatures, ensuring that products are stored under the right conditions to maximize quality and shelf life. The use of digital thermostats also allows for precise temperature adjustments and monitoring, thus preventing fluctuations that could compromise food safety.

In terms of design, the RGSSFP boasts a sleek, modern appearance that complements any retail environment. Its glass front and sides ensure maximum visibility, enticing customers to view and interact with displayed products. The case is ergonomically designed, making it easy for staff to stock items while maintaining an attractive merchandising layout.

Technologies incorporated into the RGSSFP include energy-efficient compressor systems that reduce overall power consumption compared to traditional refrigeration units. These systems are complemented by advanced insulation materials that enhance thermal performance, keeping the interior cool with minimal energy usage. Additionally, integrated LED lighting illuminates the interior of the display case, showcasing the products effectively while adding to energy savings.

Another characteristic of the Hussman RGSSFP is its user-friendly operation. It features easy-to-navigate controls, allowing store staff to monitor and adjust settings with ease. Routine maintenance tasks, such as cleaning and restocking, are simplified, enhancing operational efficiency and reducing downtime.

Hussman also emphasizes hygiene, incorporating materials that are easy to clean and designed to minimize bacterial growth. This is especially crucial in a retail food environment, where cleanliness directly impacts customer health and trust.

Overall, the Hussman RGSSFP is a powerful combination of cutting-edge technology, aesthetic design, and practical functionality. It supports retailers in their mission to provide fresh, appealing products while maintaining high standards of energy efficiency and hygiene, making it an essential asset for modern food retailing.