Installation
It is dangerous to alter the specifications or attempt to modify this product in any way.
Care must be taken to ensure that the appliance does not stand on the electrical supply cable.
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
Technical Data |
| Heating elements rating | |
Dimensions of recess |
| Supply voltage (50 Hz) | |
Height | 820 mm | Connected load, | 90 W |
Width | 600 mm |
|
|
Depth | 550 mm |
|
|
Dimensions of the appliance cavity |
|
| |
Height | 815 mm |
|
|
Width | 596 mm |
|
|
Depth | 550 mm |
|
|
Freezer Gross capacity | 108 litres |
Freezer Net capacity | 100 litres |
Electrical connection
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
WARNING:THIS APPLIANCE MUST BE EARTHED.
The manufacturer declines any liability should this safety measure not be observed.
If the plug that is fitted to your appliance is not suitable for your socket outlet, it must be cut off and the appropriate plug fitted.
Remove the fuse from the cut off plug.
The cut off plug should then be disposed of to prevent the hazard of shocks in case it should be plugged into a 13amp socket in another part of your home.
Important
The wires in the mains lead are coloured in accordance with the following code:
Green andYellow | - Earth |
Blue- Neutral
Brown- Live
If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug, proceed as follows:
6
GREEN & YELLOW | 13 AMP. FUSE |
|
13 AMP |
| BROWN |
| BLUE |
D207 | CORD CLAMP |
|
1.Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter
«E» or the earth symbol or coloured green and yellow.
2.Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter «N» or coloured black.
3.Connect the brown (live) wire to the terminal in the plug which is marked with the letter «L» or coloured red.
4.Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.The plug moulded onto the lead incorporates a fuse. For replacement, use a 13amp BSI362 fuse. Only ASTA or BSI approved fuses should be used.
The plug must not be used if the fuse cover/carrier is lost.The cover/carrier is indicated by the coloured insert at the base of the plug.
A replacement cover/carrier must be obtained from your local Service Force Centre.