Heatcraft Refrigeration Products H-IM-82B Models PTT099H2C and PTT128H2C, 208-230V/3PH/60HZ

Page 17

 

 

 

 

 

PRIMARY SINGLE PHASE PROTECTION PROVIDED

 

 

 

 

 

 

 

 

USE COPPER CONDUCTORS ONLY

 

 

 

 

 

 

CC

GND

 

 

 

FACTORY WIRING

 

 

 

 

 

 

 

 

 

FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WHEN PLUG

 

 

 

 

 

T1

L1

 

 

 

 

NOT

 

 

 

 

 

 

 

 

 

 

PROVIDED)

Room Thermostat Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

L2

 

 

 

 

 

 

-Room temp sensor has 59" lead length

 

 

 

 

 

 

 

 

 

 

 

-Defrost sensor has 59" lead length and a blue label.

 

 

 

T3

L3

 

 

208-230V/3PH/60HZ

 

-(3) Hours of compressor run time between defrosts.

 

 

 

 

 

 

 

 

 

 

 

-Defrost termination temperature = 3.5°C / 38°F

 

 

 

 

 

 

 

 

 

 

 

Approximate dial settings of room thermostat dial:

 

 

 

 

 

 

 

 

 

 

 

0 - Unit Off ( Not an electrical disconnect)

 

 

PFC

WN

 

 

 

 

 

 

 

1 - 52°F / 11°C

 

 

L1

T1

 

 

 

 

 

 

 

3 - 45°F / 7°C

 

 

 

 

 

 

 

 

 

 

 

4 - 41°F / 5°C

 

 

 

 

 

 

 

 

 

 

 

5 - 38°F / 3°C

 

 

 

 

CFM

 

 

 

 

 

 

6 - 34°F / 1°C

 

 

TFC

WN

 

 

 

 

 

 

 

Minimum compressor run time - 1 minute

 

 

 

 

 

 

 

 

 

 

 

Minimum compressor off time - 4 minutes

 

 

 

 

CFM

Large

 

 

 

 

 

 

 

 

 

Outdoor Units Only

 

Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

BLUE

 

 

 

 

 

 

 

 

YELLOW

L

C

BLACK

 

 

CC

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

RT

 

 

 

 

 

 

 

 

 

 

 

 

WN

 

DLT

WN

WN

 

 

 

 

 

 

 

 

 

 

 

 

DLH

Outdoor Units Only

 

 

 

 

 

YELLOW

 

 

YELLOW

WHITE

GRAY

GRAY

BLUE

 

 

 

 

 

 

 

 

 

 

 

CCH

 

 

 

 

 

 

 

 

 

BLACK

 

BLACK

 

 

 

 

 

 

 

 

 

BLACK

 

EFM

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFM

 

 

 

 

 

 

 

 

 

 

 

 

EFM

Large Cabinet

 

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

L1 L3

COMPRESSOR

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC --

COMPRESSOR CONTACTOR

DLH --

DRAIN LINE HEATER

HL --

HEATER LIMIT THERMOSTAT

RT --

ROOM THERMOSTAT

TFC --

TEMPERATURE FAN CYCLE SWITCH

 

CCH

-- CRANKCASE HEATER

DLT --

DRAIN LINE THERMOSTAT

HPS

-- HIGH PRESSURE SWITCH

SC --

START CAPACITOR

WN --

WIRE NUT

Rev 2.47

CFM

-- CONDENSER FAN MOTOR

EFM --

EVAPORATOR FAN MOTOR

PFC

-- PRESSURE FAN CYCLE SWITCH

SR --

START RELAY

 

 

 

DH --

DEFROST HEATER

GND --

GROUND

RC --

RUN CAPACITOR

SW --

SWITCH

 

 

 

 

 

Diagram4. Wiring Diagram for System, Air Defrost 208-230/3/60

Cooler - Air Defrost Systems - Three Phase

 

Large Cabinet Models Wiring. 208-230/3/60 voltage.

 

 

(C): Models PTT099H2C and PTT128H2C.

 

 

17

5. Wiring Information

Image 17
Contents Refrigeration System UctionsOperating 1.Owners SpecificationsPerformance / Electrical Data Coolers Air Defrost Systems Freezers Electric Defrost SystemsModels PTT 021, 031, 044, 047, 063 Models PTT 052, 069, 099 Dimensional DiagramsOwners Operating Instructions Top View One System Recommended Unit Placement For PTT ModelsTop View Two Systems MinOperating Instructions PTT Models Standard Installation ProcedureDrain Line Owners Operating Instructions Freezers HOW to Change the Setpoint HOW to see the SetpointHOW to Start a Manual Defrost HOW to Enter the Hidden MenuMessage Cause Outputs Alarm SignalsSystem Standard Maintenance Guidelines Room Thermostat SettingsCooler Defrost Control Air Defrost Sequence of Operation for CoolersProblem Possible Causes Possible Corrective Steps System Troubleshooting ChartDependable. Versatile. Courteous Replacement Parts byRight source. Right parts. Right now PTT047H2B, PTT063H2B Diagram 1. PTT072H2B Cooler AirAir Defrost 208-230/1/60 B Models Freezer Electric Defrost Wiring InformationDefrost 208-230/1/60 VoltagesInformationWirig 208-230V/3PH/60HZ Models PTT099H2C and PTT128H2CWiriInformation.5g Only Freezer- Electric Defrost Systems Three Phase230/3/60 PTT069L6COptional Three-Year Extended Compressor Warranty Warranty Statement