hussman GSVM installation instructions Condensing Unit, Shelves, Thermometer

Page 10

correspond to the actual cabinet tempera- ture due to the bulb location and depend- ing on various conditions, a certain amount of time lag will be noticed between the new setting and the resulting temperature.

CONDENSING UNIT

A regular program should be set up for cleaning the fin-and -tube condenser. Normally, this cleaning is required every 3 to 4 months, but the individual store appli- cation may shorten or lengthen this time period. Dust and dirt accumulation can cause serious efficiency loss.

Access is gained to the unit area by removing the louvered grille. Before at- tempting to slide out condensing unit you must first remove the screws from the con- denser unit baffles. The unit slides for- ward to facilitate cleaning and for service. Care should be taken when pushing the unit back in, to insure that the pullout coil does not become kinked or damaged in some way. The baffle screws must be re- placed after sliding the condensing unit back into position. Double check to make sure the drain hose is in the drain pan be- fore putting the access grille back on. The rear access panel is also removable if it is necessary to work at the back of the case.

SHELVES

The GSVM4060 cabinet is equipped with 2 standard shelves for the display of your product. The 13” shelf should be lo- cated at the top and 15” shelf should be lo- cated below it. The GSVM5272 and 4072

has an additional 13” shelf as standard which should be located above the 15” shelf also.

The shelves should be positioned so they do not protrude into the front (top to bottom) air curtain. Do not use deeper shelves or allow product to protrude over the shelves into the air curtain.

THERMOMETER

A solar thermometer is provided that registers degrees ºF. The thermome- ter is located in the front center.

A solar powered thermometer is equipped with each cabinet. The ther- mometer is located in the top front center of the cabinet interior. Temperature is dis- played in Fahrenheit degrees as standard. Celsius display is available as an option.

The thermometer may be replaced by removing the two screws securing the thermometer to is mounting bracket. Re- move the sensing element from the clip.

Install the new thermometer in reverse or- der.

To clean the sensing element of the thermometer, follow the same procedure as replacement. Cleaning of the element is accomplished by using water and mild de- tergent. Be sure to wipe the element clean of any residues so proper temperatures are displayed.

10

Image 10
Contents OII Gsvm Table of Contents Table of Contents CON’T Inspection IntroductionSkid Sealing Access Panel RemovalLeveling DrainsLoading Power RequirementsPower Switch Electrical BOX Connections Shelving Maximum Weight Capacity LBS Specifications DimensionsRefrigerant RUN Fuse Power Type Amps Amps Cord ElectricalTemperature Control Shelves Condensing UnitThermometer Cleaning Interior Cleaning ExteriorLighting Refrigeration Cleaning Stainless Steel SurfacesEvacuation Model no Refrigerant Suction Pressure Head Pressure Type Evaporator FAN MotorsTrouble Shooting Charts Trouble Probable Cause SolutionTrouble Shooting Light Chart Problem SolutionGsvm Accessories Warranty and Parts Information Ordering Parts ReplacementWarranty Parts Procedure Compressor Replacement Procedure115 115 115 60 Hz Gsvm 52072 R-404A