hussman GSVM installation instructions Trouble Shooting Light Chart, Problem Solution

Page 15

4. Refrigerant overcharge 4. Purge system, evacuate and recharge.

5. Low voltage, compressor 5. Check voltage at

cycling on overload compressor should not be more than 5% below rating

Compressor runs

1.

Short of refrigerant

1.

Leak check, replace drier,

continuously. Product too

 

 

evacuate and recharge

warm

 

 

 

 

 

2.

Inefficient compressor

2.

Replace

Compressor runs

1.

Defective control

1.

Replace

continuously. Product too

 

 

 

 

cold

2.

Control sensing element

2.

Assure proper contact

 

 

not in positive contact

 

 

 

3.

Short on refrigerant

3.

Leak check, replace drier,

 

 

 

evacuate and recharge.

TROUBLE SHOOTING LIGHT CHART

PROBLEM

 

SOLUTION

Lights won’t start

 

1. Check light switch

 

 

2.Check continuity to ballast

3.Check to see if bulbs inserted properly in sockets

4.Check voltage

Lights flicker

1. Allow lamps to warm up

 

2.

Check lamp sleeve for cracks

 

3.

Check sockets for moisture and proper contact

 

4.

Bulb replacement may be necessary

 

5.

Check voltage

 

6.

New bulbs tend to flicker until used

15

Image 15
Contents OII Gsvm Table of Contents Table of Contents CON’T Introduction InspectionSkid Drains Access Panel RemovalLeveling SealingElectrical BOX Power RequirementsPower Switch LoadingConnections Electrical Specifications DimensionsRefrigerant RUN Fuse Power Type Amps Amps Cord Shelving Maximum Weight Capacity LBSTemperature Control Condensing Unit ShelvesThermometer Cleaning Exterior Cleaning InteriorLighting Cleaning Stainless Steel Surfaces Refrigeration Evacuation Evaporator FAN Motors Model no Refrigerant Suction Pressure Head Pressure TypeTrouble Probable Cause Solution Trouble Shooting ChartsProblem Solution Trouble Shooting Light ChartGsvm Accessories Ordering Parts Replacement Warranty and Parts InformationCompressor Replacement Procedure Warranty Parts Procedure115 115 115 60 Hz Gsvm 52072 R-404A