Master Bilt GT-30, GT-40 manual Trouble Shooting Guide

Page 12
TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

1.High head pressure and high back pressure:

A.Condenser coil clogged or restricted.

B.Condenser fan motor defective.

C.Air in the system.

D.Refrigeration overcharge.

2.Low back pressure and low head pressure:

A.Expansion valve restriction.

B.Refrigerant undercharged.

C.Leak in system.

3.Pressures normal – cabinet warm:

A.Refrigerant undercharged.

B.Control set too warm.

4.Compressor starts and runs – but cycles on overload:

A.Low voltage.

B.Overload protector defective.

C.High head pressure (see#1).

5.Compressor will not start – hums, but cycles on overload:

A.Low voltage.

B.Relay defective.

C.Overload defective.

D.High head pressure (see #1).

6.Cabinet sweating:

A.High ambient humidity.

B.Defective condensate heater.

7.Cabinet not cycling – coil blocked with frost:

A.Defective temperature controller.

B.Refrigerant overcharged.

C.Location too hot.

D.Condenser clogged.

E.Condenser fan motor defective.

F.Defrost heater not operating.

8.Gravity coil will not defrost (coil loaded with ice or frost)

A.Solenoid in timer sticking closed, preventing unit from going defrost.

B.Defrost termination thermostat is defective.

C.Safety thermostat is defective.

D.Timer defrost is not set at minimum 34 minutes

E.Defective defrost coil heater.

9.Defrost cycle too long.

A.Defective time clock solenoid.

B.Defective defrost end thermostat and/or defective safety thermostat.

12

Image 12
Contents J-Version GT-30& GT-40 Installation & Operations Manual908 Highway 15 North New Albany, MS Phone PN Rev 03/12/07 LNPage TABLE OF CONTENTS INTRODUCTION STORE CONDITIONSNOTICE DANGERWARNING LABELS AND SAFETY INSTRUCTIONS GROUND REQUIRED FOR SAFE OPERATIONNOTICE TO EMPLOYERS PRE-INSTALLATIONINSTRUCTIONS INSTALLATION INSTRUCTIONS GENERAL INSTRUCTIONSINSPECTION FOR SHIPPING DAMAGE NOTICE TO STORE OWNERS / MANAGERSMECHANICAL STARTUPTHEROMSTAT CHECK Leveling CabinetDEFROST AND TEMPERATURE CONTROL SETTINGS AUTOMATIC EXPANSION VALUE GT SERIES CABINETS CLEANINGREFRIGERATION SYSTEM AND OPERATION EXTERIOR PARTS NOMENCLATURE Drain Pan and Light Shield Removal Light Shield Drain PanSERVICE INSTRUCTIONS TROUBLE SHOOTING GUIDE Lamb holder Fixed Temperature Control Timer Toggle Switch Toggle Switch Lights and HeatersSide Panel Heater, LH Lamb holder Spring 17-00409 23-01698 23-01699 19-13765ACCESSORIES SALE AND DISPOSALOWNER RESPONSIBILITY