Master Bilt GT-40, GT-30 manual Drain Pan and Light Shield Removal, Light Shield Drain Pan

Page 11
Drain Pan and Light Shield Removal

Drain Pan and Light Shield Removal

Light Shield

Drain Pan

SERVICE INSTRUCTIONS

OPERATION CONDITIONS AND PRESSURES

To remove the drain pan, remove screws along the front face of the drain pan. Lift the rear of the pan up and out of the drain trough. Slide pan towards you and out.

Reverse procedure to install.

To remove the light shield, remove screws along the front face of the light shield. Pull the light shield towards you and out. Reverse procedure to reinstall.

With room ambient temperature of +80 oF and cold cabinet (unit cycling on control):

Suction pressure – 5 to 9 psig.

Head pressure – 210 to 260 psig.

Typical operating pressures for a properly charged unit operating at 0°F or lower box temperature, check pressures immediately before normal off cycle expect a tolerance of ± 5 psig high side, and ±1 psig low side.

11

Image 11
Contents PN Rev 03/12/07 LN J-VersionGT-30& GT-40 Installation & Operations Manual 908 Highway 15 North New Albany, MS PhonePage TABLE OF CONTENTS DANGER INTRODUCTIONSTORE CONDITIONS NOTICENOTICE TO EMPLOYERS WARNING LABELS AND SAFETY INSTRUCTIONSGROUND REQUIRED FOR SAFE OPERATION NOTICE TO STORE OWNERS / MANAGERS PRE-INSTALLATIONINSTRUCTIONSINSTALLATION INSTRUCTIONS GENERAL INSTRUCTIONS INSPECTION FOR SHIPPING DAMAGELeveling Cabinet MECHANICALSTARTUP THEROMSTAT CHECKDEFROST AND TEMPERATURE CONTROL SETTINGS REFRIGERATION SYSTEM AND OPERATION AUTOMATIC EXPANSION VALUE GT SERIES CABINETSCLEANING EXTERIOR PARTS NOMENCLATURE SERVICE INSTRUCTIONS Drain Pan and Light Shield RemovalLight Shield Drain Pan TROUBLE SHOOTING GUIDE 17-00409 23-01698 23-01699 19-13765 Lamb holder Fixed Temperature Control TimerToggle Switch Toggle Switch Lights and Heaters Side Panel Heater, LH Lamb holder SpringOWNER RESPONSIBILITY ACCESSORIESSALE AND DISPOSAL