McCall Refrigeration MCCR1-S manual Installation, Location

Page 8

McCall Series I Reach-In Manual

Installation

Location

Cabinets represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet, 1000 pounds (450 kg) per door section. Reinforce the floor if necessary to provide for maximum loading. For the most efficient operation, be sure to provide good air circulation inside and out. The location should be selected so that the power cord can be connected without any extensions.

Inside Unit

Take care not to block airflow to the fans or heating elements and allow space along the front, back and sides.

Outside Unit

Be sure that the unit has access to ample air; avoid hot corners and locations near stoves and ovens. Provide a minimum clearance of 12” (30cm) above the unit that is open to the front.

Door Removal

The doors can be removed during installation if necessary. Remove the door by opening the door to 90˚, lift it up and ease it out of the hinge brackets

Leg, Caster, Utility Base Installation

Some cabinets may weigh over 1000 pounds (450 kg). Use a lifting device capable of supporting the unit when removing skid or installing legs, casters

WARNING or utility base.

To install the legs, or casters refer to Figure 1. To install the utility base, refer to Figure 2. Proceed as follows:

1.Remove unit from skid.

2.Raise unit to access leg/caster mounting holes on bottom of unit.

3.Attach the legs, casters or utility base to bottom of cabinet using hex head bolts.

Leveling

After the cabinet has been placed in the desired location, cabinets with legs must be leveled. Level units from front to back and from side to side. Leveling will insure proper door operation and removal of condensate. Cabinets with casters must have the caster brake set so the cabinet cannot move.

Stabilizing

It is very important that all legs are properly adjusted to keep the cabinet level, evenly distribute the weight and to make sure the unit will not rock, lean or be unstable.

Figure 1. Leg or Caster Installation

Figure 2. Utility Base Installation



Image 8
Contents Service, Installation and Care Manual Important Warning And Safety Information Receiving And Inspecting The Equipment ContentsSerial Number Location Series Temp Configuration Section Doors Model NumbersIntroduction Refrigeration SystemSpecifications Reach-In Refrigerators Hinged Doors Standard Width & DepthPass-Thru Refrigerators Hinged Doors Standard Width Installation LocationPlug Configurations Electronic Temperature Control Operation Power Up Heated Cabinet OperationMaintenance Preventing blower coil corrosion MCCR1, MCCRPT1 Solid Doors MCCR1, MCCRPT1 Glass DoorsMCCR2, MCCR2-SL Glass Doors MCCRPT2, MCCR3 Solid Doors MCCRPT2, MCCR3 Glass Doors Freezer Wiring Diagrams MCCF1 Solid DoorsFreezer Wiring Diagrams Refrigerator/Freezer Combination Wiring Diagram MCCH1, MCCH2, MCCH3 Solid & Glass Doors Compressor Diagrams Coil, evaporatorReplacement Parts MCCR2 Solid Doors MCCR2, MCCR2-SL Solid & Glass DoorsMCCRPT1 Glass Doors MCCR3, MCCRPT2 Solid & Glass DoorsMCCF1, MCCDRL2 Solid Doors MCCDRL2 Glass Doors MCCF1 Glass DoorsMCCF2 Solid Doors MCCF3 Solid Doors MCCF2 Glass DoorsShelf Replacement Parts MCCF3 Glass DoorsMCCDTR1 Solid Doors All Heated ModelsLabor Of 1-Hour Is Allowed To Replace Labor Of 2 Hours To ReplaceLabor Of 3 Hours To Replace Labor Of 4 Hours To ReplaceMcCall Series I Reach-In Manual General Conditions Thank you for choosing McCall

MCCR1-S specifications

The McCall Refrigeration MCCR1-S is a top-of-the-line refrigeration unit designed for both commercial and industrial applications. Known for its robust performance, efficiency, and reliability, this model stands out in the crowded market of refrigeration systems.

One of its main features is the impressive cooling capacity, which allows it to maintain optimal temperatures even in high-demand environments. The MCCR1-S uses advanced compressor technology, ensuring rapid cooling while minimizing energy consumption. This is particularly important for businesses looking to reduce operational costs without sacrificing performance.

Energy efficiency is further enhanced by the use of eco-friendly refrigerants that comply with modern environmental regulations. These refrigerants not only have a lower global warming potential but also contribute to lower overall energy bills. The MCCR1-S is designed with an energy-efficient system that is optimized to function effectively under various load conditions, providing consistent performance while reducing energy waste.

The MCCR1-S also boasts an intuitive control system that allows for precise temperature management. It features a user-friendly digital display that enables users to set and monitor temperatures with ease. Some models come equipped with smart connectivity, allowing users to control and monitor the refrigeration unit remotely via a mobile application. This technology enables operators to troubleshoot issues before they escalate, ensuring uninterrupted service.

In terms of durability, the MCCR1-S is built with high-quality materials that are resistant to corrosion and wear, ensuring a long lifespan. The unit is designed to endure harsh operating conditions, making it a reliable choice for various settings, including restaurants, warehouses, and distribution centers.

Additionally, the MCCR1-S features ample storage capacity, allowing businesses to store a significant amount of perishable goods. Its organization and shelving systems are designed to maximize space, making it an ideal choice for establishments with high inventory needs.

In conclusion, the McCall Refrigeration MCCR1-S combines advanced technology, energy efficiency, and robust performance, making it an essential asset for any commercial or industrial refrigeration needs. Its reliability, user-friendly features, and eco-friendly design set it apart from other models in the market, ensuring it meets the demands of modern businesses.