10 Installation

Leveling Information

It is recommended that the unit is level.

Installation

1.

Plug in the powercord.

2.

Gently push the unit into position. Be careful not to kink the

 

water supply line or entangle the electrical cord.

1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown

1

3.

Re-check the leveling, from front to back and side to side. Make

 

any necessary adjustments. The unit’s top surface should be

 

approximately 1/8" below the countertop.

4.

Remove the tape from the glass shelves and wipe out the inside

 

of the unit with a clean, water-dampened cloth.

Relocating the Shelves

Both the glass shelves in the refrigerator and the inner door shelves can be moved to accommodate your bottles, cans and containers.

Glass Shelves on Right-Hand Hinge Units

• Open door fully, grasp shelf firmly, lift front edge slightly, and

pull straight out.

2.If the unit is not level, adjust the feet on the corners of the unit as necessary (not available in CO29 models).

Turn Foot to Adjust

3.Check the levelness after each adjustment and repeat the previous steps until the unit is level.

INSTALLATION TIP

If the room floor is higher than the floor in the cut-out opening, adjust the rear feet to achieve a total unit rear height of 1/8" less than the opening’s rear height. Shorten the unit height in the front by adjusting the front feet. This allows the unit to be gently tipped into the opening. Readjust the front feet to level the unit after it is correctly positioned in the opening.

• Choose new location and slide shelf onto the appropriate rib.

Glass Shelves on Left-Hand Hinge Units

Pull shelf out about 6” to clear the wall’s molded protrusion.

Tilt right-hand edge of shelf up.

Keeping at this angle and hugging the right wall, pull the shelf out.

Choose new location and insert over ribs, tilting right-hand edge up. Push in, then lower shelf onto ribs.

Door Shelves

First pull shelf up at a 45° angle, then straight out (see Figure 39).

Choose new location and line up on bosses. First push straight in, then down at a 45° angle.

Installation Troubleshooting

Q: Problem

The door remains open unless it is pushed closed.

A: Solution

The hinges should be self-closing when the door is open approximately 8". If this is not the case, make sure the closers are clean, greased and installed correctly. Also, re-check leveling from front to back of the unit and readjust if necessary. Make sure that pivot plate is installed correctly.

Q: Problem

The custom overlay door was designed to align with the rest of the cabinet doors, but the unit has crept forward.

A: Solution

Make sure that the electrical cord and water supply line are not obstructing the installation.

Level & Install Unit

11

Image 13
Contents Install Guide Table of Contents General Precautions Safety Alert DefinitionsSafety Precautions Product Registration Models Covered Exterior CleaningTools / Material Required Inspect & PlanPrepare Site Cut-Out Dimensions1175, 1075 & 75F Series SeriesProduct Dimensions ADA24RGLS Series ADA24RGLB SeriesSide-By-Side Installation Door Swing DimensionsPower Supply Other Site RequirementsDoor Reversability Door Alignment and AdjustmentReversing the door Standard DoorsPrepare door for reinstallation For black or white doors Install bottom hingeInstall top hinge, and door Prepare door for reinstallationStaining and final finish application Wood Trim FinishingFinal finish-only application To insert a rack in the cabinetPanel Dimensions Door Panel InstallationDoor Panel Installation Custom 1/4 Thick Door Panel InsertInstallation InstallationInstallation Troubleshooting Leveling InformationInstallation Guide