4 Prepare Site
Your
WARNING
Unit can NOT be installed behind a closed cabinet door.
WARNING
SHOCK HAZARD — Electrical Grounding Required.
•Never remove the round grounding prong from the plug and never use a
•Never use an extension cord to connect power to the unit.
IMPORTANT
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.
Cut-Out Dimensions
1175, 1075 & 75F Series
Follow the
24"
to7"
4"
1115 Series
Follow the
24” | |
to |
|
35" | 7" |
| |
| |
|
29 Series
Follow the
Filler Panel (Not Provided by
Typical |
|
Counter |
|
Height |
|
| |
to | 24" |
Minimum | |
| |
Height | 7" |
to |
|
|
ADA24 Series
Follow the
24"
32”
7"
4"
Prepare Site | 3 |