To defrost:
1.Turn unit off.
2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).
3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or
4.Dampen a soft sponge or
5.When the interior is dry, turn unit back on.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before cleaning the condenser.
To remove and replace the grille for access to the condenser fins, follow this procedure:
1
2 | ULIN_0203_A |
Figure 9
1.Disconnect electrical power to the unit.
2.Loosen two screws (Figure 9, 1) completely.
NOTE: Screws are held in the grille by
3. Remove the grille.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
CAUTION
DO NOT use any type of cleaner on the condenser unit.
4.Clean the condenser coil (Figure 9, 2) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
5.Position the grille to align the mounting screws with the holes in the cabinet.
6.Secure, but do not
7.Reconnect power to the unit.
Leveling |
1 |
ULIN_0833_A |
Figure 10
1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 10).
1 | ULIN_0044_A |
|
Figure 11
2.If the unit is not level, adjust the feet on the corners of the unit as necessary (Figure 11).
3.Check the levelness after each adjustment and repeat the previous steps until the unit is level.