U-Line manual Temperature Display Selection, Checking Product Temperature, 2175BEVS, 2175BEVOL

Page 8
Temperature Display Selection

A DISPLAY OFF mode is available through the control panel. This mode allows you to control whether the display (Figure 4, 3) will be ON or OFF whenever the door is closed. The icon touch sequence that follows will switch between both modes:

NOTE: These are product temperatures, not air temperatures.

1.Touch and hold the WARMER icon (Figure 4, 2), and within five seconds press the POWER icon (Figure 4, 1) three times.

2.The display will be either visible or dark when the door is closed.

3.To return to the previous mode, repeat Step 1.

Temperature Display Selection

U-Line products supplied for 110 VAC operation have temperatures displayed in a default Fahrenheit (°F) configuration (Figure 4, 3). Models supplied for 220 VAC operation have temperatures displayed in a default Celsius (°C) configuration.

The display can easily be adjusted for either type of temperature display. Press and hold the LIGHT icon (Figure 4, 5) and within five seconds press the COOLER icon (Figure 4, 4) three times to change the display as desired.

Temperature Display

To display actual temperatures:

1.Press and hold the WARMER icon (Figure 4, 2) for approximately five seconds and release when the °F symbol in the display (Figure 4, 3) begins to flash.

2.After approximately 10 seconds, the display will return to the set-point temperature.

Checking Product Temperature

ULIN_0093_A

Figure 5

To check the actual product temperature in your unit, insert an accurate thermometer into a plastic (non- breakable) bottle that is partially filled with water. Tighten the bottle cap securely (Figure 5).

Place the bottle in the desired area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small increment (See

ADJUSTING TEMPERATURE).

Factors which affect the internal temperatures of the cabinet include:

Temperature setting.

Ambient temperature where installed.

Number of times and length of time the door is opened and closed.

Installation in direct sunlight or near a heat source.

Adjusting Temperature

IMPORTANT

Adjust the set-point temperature in single increments, and wait 24 hours for the temperature to stabilize before rechecking.

1

2

3

4

5

ULIN_0184a_A

Figure 6

8

2175BEVS, 2175BEVOL

Image 8
Contents Beverage Center 2175BEVS, 2175BEVOL 2175BEVS2175BEVOLUse and Care Guide Warranty Registration Please Record Your Model Information1 Introduction Model Number2 Table of Contents This page intentionally left blank Safety Alert Definitions General Precautions3 Safety Precautions DANGERThe Right Temperature for Wine 4 Product FeaturesÉchelon Beverage Center Initial Startup Interior LightingElectronic Control Panel 5 OperationAdjusting Temperature Temperature Display SelectionTemperature Display Checking Product TemperatureNormal Operating Sounds Wine Stocking RecommendationsStorage, Vacation, Moving Product DisposalWine Selections Suggestions Suggestions for Matching Food and WineCommon Food and Wine Matches 6 Wine GuideGuide to Common Styles of Wine Common Tasting TermsRed Wines White WinesGeneral Cleaning Maintenance7 Cleaning and Maintenance Exterior Cleaning As RequiredInterval - Every Three Months Condenser CleaningLeveling Door Alignment Check and Adjustment When properly alignedLight Bulb Replacement Wine Rack Removal/InstallationFinal finish-onlyapplication Wood Trim FinishingStaining and final finish application Before Calling for Service If Service is RequiredReplacement Parts 8 ServiceTroubleshooting Guide ELECTROCUTION HAZARDElectronic Control Quick Guide This page intentionally left blank 2175BEVS, 2175BEVOLThis page intentionally left blank U-LineCorporation Limited Warranty