WARNING
The distance between the hob and the lower part of the hood must be at least 65 cm.
The air collected must not be conveyed into a duct used to blow off smokes from ap- pliances fed with an energy other than elec- tricity (central heating systems, ther- mosiphons,
Comply with the official instructions provided by the competent authorities in merit when installing the disposal duct. In addition, exhaust air should not be discharged into a wall cavity, unless the cavity is designed for that purpose.
The room must be well aerated in case a hood and some other heat equipment fed with an energy other than electricity (gas, oil, coal heaters, etc) operate at the same time.
In fact the intake hood, disposing of air, could create a vacuum in the room. The vacuum should not exceed 0,04mbar. This prevents the gas exhausted by the heat source from being intaken again. It is therefore advisable to ensure the room contains air taps able to ensure a steady flow of fresh air.
ATTENTION: This appliance must be grounded.
The following warning is valid in the United Kingdom only:
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
–the wire which is coloured green and yellow must be connected to the termi-
nal in the plug which is marked with the letter E or by the earth symbol [ ], or coloured green or green and yellow;
–the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black;
–the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
When making the electrical connections, check that the current socket has a ground connection and that the voltage values cor- respond to those indicated on the data plate inside the appliance itself.
In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensu- ring omnipolar disconnection from the elec- tricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation.
Always switch off the electricity supply be- fore carrying out any cleaning or servicing operations on the appliance.
USE
Avoid using materials which could cause spurts of flame (flambées) near the ap- pliance.
When frying, take particular care to prevent oil and grease from catching fire. Already used oil is especially dangerous in this re- spect. Do not use uncovered electric grates.
To avoid possible risks of fire always com- ply with the indicated instructions when cleaning
MAINTENANCE
Thorough servicing guarantees correct and
Particular care must be paid to the anti- grease filters which must be periodically cleaned in relation to use (at least once every two months). Remove the
Use lukewarm water and neutral detergent to clean painted appliances. Never use products containing abrasives.
Take great care to prevent the use of cor- rosive or abrasive products when cleaning steel, copper or brass appliances. It is advi- sable to use specialized products accord- ing to the manufacturer’s instructions.
DESCRIPTION
This appliance consists of a telescopic struc- ture, a hood and telescopic flue which covers the telescopic structure itself.
The appliance can be used in both the filtering and ducting version.
In the Filtering version (Fig. 1), the air and vapours conveyed by the appliance are depu- rated by carbon filters and recirculated around the room through the air vents of the flue.
ATTENTION: When using the Filtering version, two carbon filters must be installed plus an air switch A (Fig. 1). Positioned in the upper part of the structure, this allows the air to be recirculated throughout the room.
In the Ducting version (Fig. 2), cooking va- pours and odours are conveyed directly to the exterior through an outlet flue which exits from top or back of the apparatus and through the ceiling. Use of carbon filters is therefore unnec- essary.
INSTALLATION
It is advised to follows carefully all the as- sembling steps and to make sure, once the assembling operation is over, that the ap- pliance is fixed steadily; it is moreover ad- vised to have skilled workers to assemble it.
Remove the
This will make the appliance easier to handle. To remove the
Proceed with these instructions in reverse when refitting the filters.
The following operations are essential for assembly:
–Install the wiring system within the decora- tive pipe.
–Prepare the air venting hole if your applian- ce is to be installed in the Ducting version.
Once having established the desired position, assemble the equipment in the following way:
INSTALLING THE DUCTING VERSION:
Using the relative boring template, make holes in the ceiling in alignment with your hob. Mind thet one of the axes of the boring tem- plate must be in correspondence with the axis of the controls of the hood.
Since this model can dispose of stale air from either the top or side, position the telescopic structure through openings A or B (Fig. 4) as required, in compliance with the following in- structions:
–The side of the structure with opening B (Fig. 4) must always point towards a short side of the hood.
Fix the telescopic structure to the ceiling using the larger diameter washers and screws, to- gether with the screw anchors supplied with the hood, after having made the air hole and installed the wiring system within the upper telescopic flue.
Adjust the height of the telescopic structure by means of the four fixing screws D (Fig. 4). Remember that the hood is 345 mm in height and that it must be at least 650 mm from the hob (Fig. 5).
Prepare the air disposal pipe and the electric power cable.
Insert the upper telescopic flue into the struc- ture.
Fix the upper telescopic flue to the plate of the structure anchored to the ceiling by means of the two screws A (Fig. 6).
Push in the lower telescopic flue right up to the top, partially tightening screws B (Fig. 6) and temporarily resting the pipe on these. During this operation, check that the fixing holes C (Fig. 6) of the lower telescopic flue point downwards.
Fix the hood to the lower plate of the telescopic structure using the four supplied nuts and rela- tive washers (Fig. 7).
If the model you bought requires it you have to insert the two plastic spacing bars (Fig. 6D) into the side pitches of the telescopic structure. The spacing bars are supplied.
Apply air union flange A (Fig. 8) to the hood through the lower part of opening B (Fig. 4) on the structure.
Fix the previously installed air disposal flue to the union flange on the hood and make the relative electrical connections.