Instructions for the installer
3.2Burner and nozzle characteristics table
Burner
Auxiliary (1)
Semi rapid (2)
Rapid (3)
Ultra rapid (4)
Rated
heating
capacity
(kW)
1.05
1.75
2.3
3.5
LPG – G30/G31 30/37 mbar
Nozzle |
|
| Reduced |
| Flow rate |
| Flow rate | ||||
diameter |
|
| mm |
| flow rate |
| g/h G30 |
| g/h G31 | ||
1/100 mm |
| 1/100 |
| (W) |
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
50 |
| 30(*) |
|
| 28 (**) |
| 350 |
| 76 |
| 75 |
|
|
|
|
|
| ||||||
65 |
| 33(*) |
|
| 32 (**) |
| 450 |
| 130 |
| 128 |
|
|
|
|
|
| ||||||
75 |
| 45(*) |
|
| 42 (**) |
| 800 |
| 166 |
| 164 |
|
|
|
|
|
| ||||||
94 |
| 65(*) |
|
| 63 (**) |
| 1.6 |
| 253 |
| 250 |
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point “4.1 Regulation of minimum for natural gas”.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Auxiliary (1)
Semi rapid (2)
Rapid (3)
Ultra rapid (4)
1.05
1.75
2.3
3.5
Rated
Nozzle diameter
1/100 mm
72
97
103
133
Reduced flow rate
(W)
350
450
800
1500
Burner
heating
capacity
(kW)
Town gas – G110 8 mbar
Auxiliary (1)
Semi rapid (2)
Rapid (3)
Ultra rapid (4)
1.05
1.75
2.3
3.3
Nozzle diameter
1/100 mm
145
185
220
290
Reduced flow rate
(W)
350
450
800
1500
Values for town gas are based on category III 1a2H3+ appliances.
3.3Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
31