4 FINAL OPERATIONS

After carrying out the above adjustments, remount in reverse order to the instructions given in paragraph “3.1 Replacement of nozzles on the hob”.

After adjustment to a different kind of gas from the one for which the appliance has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. The label is available from your nearest Authorised Assistance Centre.

4.1Regulation of minimum for town gas and natural gas

Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the

model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (when you turn the knob quickly from maximum to minimum position, the flame should not go out). Repeat this operation for all the gas taps.

4.2Regulation of minimum for LPG

To regulate the minimum for LPG, fully tighten the screw inside or next to the gas tap pin (depending on the model) in a clockwise direction.

The diameters of the by-passes for each burner are given in table “3.2 Burner and nozzle characteristics table”.

4.3Lubrication of gas taps

With time it may happen that the gas taps get blocked and hard to turn. Clean them inside and re-grease them. This operation must be done

by an authorised person.

32

Image 13
Contents Summary Final Operations Using the HOB Cleaning and MaintenancePositioning of the HOB Instructions for Safe and Proper USE IntroductionData Plate on the Protective Cover Must Never be Removed Positioning of the HOB Instructions for the installerAttachment to support structure, flush-mounting model Instructions for the installer Instructions for the installer Electrical connection Power line is adequately earthedDischarge of combustion products Ventilation requirementsConnection to LPG Gas connectionReplacement of nozzles on the hob Adjustment to Different Types of GASArrangement of burners on cooking hob Burner and nozzle characteristics tableRegulation of minimum for town gas and natural gas Final OperationsRegulation of minimum for LPG Lubrication of gas tapsInstructions for the user Using the HOBIgnition of the burners Diameter of receptacles Practical advice for using the burnersCleaning the stainless steel Cleaning and MaintenanceCleaning of cooking hob components Instructions for the user