Instructions for the installer
Installation with the flexible hose must be carried out so that the length of the piping does not exceed 2 metres fully extended; make sure that the hoses do not come into contact with moving parts and that they are not crushed in any way.
8.1Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following the guidelines established by the regulations in force.
Make sure that the feed pressure complies with the values indicated in the table at point “9.2 Burner and nozzle characteristics table”.
8.2Room ventilation
The appliance may only be installed in permanently ventilated rooms, as specified by the standard
8.3Extraction of the products of combustion
Extraction of the products of combustion must be ensured by means of hoods connected to a natural draught chimney whose efficiency is assured or via forced extraction. An efficient extraction system requires precision planning by a specialist qualified in this area and must comply with the positions and distances indicated by the regulations. When the job is complete, the installer must issue a certificate of conformity.