9.2Burner and nozzle characteristics table

 

RATED

 

 

 

 

 

 

Rapid

HEATING

 

 

LPG – G30/G31 28/37 mbar

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

(KW)

 

 

 

 

 

 

 

 

Nozzle

 

By-pass

Reduced

Capacity

Capacity

 

 

diameter

 

capacity

 

 

 

1/100 mm

g/h G30

g/h G31

 

 

1/100 mm

(W)

 

 

 

 

 

Auxiliary (1)

1.05

50

 

30

400

76

75

Semi-rapid (2)

1.8

65

 

33

500

131

129

Rapid (3)

3

85

 

45

800

218

214

Ultra-rapid (4)

3.9

100

 

65

1600

284

279

 

RATED

 

 

 

 

 

 

Burner

HEATING

 

 

NATURAL GAS – G20 20 mbar

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

(KW)

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced capacity

 

 

 

1/100 mm

 

(W)

 

Auxiliary (1)

1.05

 

 

72

 

400

 

Semi-rapid (2)

1.8

 

 

97

 

500

 

Rapid (3)

3

 

 

115

 

800

 

Ultra-rapid (4)

3.9

 

 

135

 

1600

 

 

 

 

 

 

 

 

 

To identify the burners on your hob, refer to the drawings in point “4.

KNOW YOUR APPLIANCE“.

39

Image 18
Contents Contents Precautions for use Instructions for USEInstructions for disposal Instructions for Disposal OUR Environmental CareSafety instructions Safety InstructionsInstructions for the User Know Your ApplianceUsing the HOB Gas hobPractical tips for using the burners Pan diametersCleaning the gas components Cleaning and MaintenanceCleaning stainless steel Ordinary daily cleaningHeights for type a installation empty base Instructions for the installerInstalling the Appliance PositioningHeights for type B installation full base Supporting base Mounting for type a installations Mounting for type B installations Electrical connection Do not remove this plate for any reasonGAS Connection Connection with rigid copper hoseConnection with flexible steel hose Connection to liquid gas Room ventilationExtraction of the products of combustion Replacement of nozzles on the hob Adaptation to Different Types of GASBurner and nozzle characteristics table LPG G30/G31 28/37 mbarFinal Operations for GAS Appliances Adjusting the minimum for town and natural gasAdjusting the minimum for liquid gas Lubrication of gas taps