Smeg SE435XT manual Conversions, Changing the Type of Power Supply

Page 8

CONVERSIONS

Disconnect the appliance from the mains supply prior to any conversions being carried out.

7)CHANGING THE TYPE OF POWER SUPPLY

Although they leave our factory preset for single- phase connection, certain appliances may by converted to the threephase system.

Comply with the following instructions:

a)Remove the hotplate from the top of the cabinet, overturn it, unscrew screw "Z" and remove under part (see fig. 9).

b)Shift connecting plate on terminal according to the following chart. This chart is also affixed to the hob.

c)Insert a supply cable of adequate section (see chart par. 10) through core hitch on the terminal board.

d)Connect the phase and earth wires to the relative terminal board.

e)Fix the supply cable in place using clamp.

f)Refit the hotplate, complying with the above instructions in reverse.

FIG. 9

FIG. 10

8

Image 8
Contents Tipo PAZ04 MOD. SE435XT Description of the HOT Plates USE Switching on the Electric PlatesHOW to USE the Electric Plates USE Cleaning HotplateFixing the HOT Plate InstallationInstalling the HOT Plate Electrical Connections Changing the Type of Power Supply ConversionsPower of Electrical Components Denominations W Type and Section of the Power CablesServicing Replacing the Electrical ComponentsTechnical Data Technical Assistance and Spare Parts