5.2Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance “X” is reached indicated in the chart in paragraph “5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

Burnerheating capacity

LPG – G30/G31 28/37 mbar

Nozzle

 

 

Reduced

 

 

 

diameter

 

By-pass

Flowrate

 

Flowrate

 

flowrate

 

1/100

 

1/100 mm

g/h G30

 

g/h G31

 

(W)

 

mm

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

1.05

 

 

 

 

Semirapid

1.65

 

 

 

 

 

Rapid

 

2.55

 

 

 

 

Rapid large

3.1

 

 

 

 

Ultra rapid (5)

3.3

 

 

 

 

 

Double

 

Internal

 

0.8

crown

 

 

 

 

 

External

3.3

 

 

 

 

Fish pan

 

2

48

 

30 (1)

380

 

 

 

380

62

30 (1)

 

 

 

650

76

37 (2)

 

 

 

750

85

43

 

 

 

1200

87

55 (4)

 

 

 

380

42

30 (1)

 

 

 

1200

87

55 (4)

 

 

 

750

67

43 (3)

7675

120 118

185 182

225 221

240236

58 57

240236

145143

(1)= 33 for valveless appliances. (2)= 40 for valveless appliances. (3)= 45 for valveless appliances. (4)= 65 for valveless appliances.

30

Image 10
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Positioning of the HOB Instructions for the installerAttachment to support structure Instructions for the installer Electrical Connection GAS Connection Ventilation of rooms Connection to LPGDischarge of combustion products Adaptation to Different Types of GAS Removing the hobRegulation for LPG LPG G30/G31 28/37 mbarRegulation of primary air Regulation for natural gasG25 G30/G31 Regulation of minimum for natural gas Final OperationsRegulation of minimum for LPG Burners Arrangement of burners on hobLubrication of gas taps This must be done by a qualified technicianInstructions for the user Using the HOBIgnition of the burners Diameter of the pans Practical advice for using the burnersUsing a griddle plate Burners Min. and max. in cmCleaning Cleaning and MaintenanceRinse thoroughly and dry with a soft cloth or deerskin Ignition plugs and safety devices Cleaning of cooking hob componentsCover