Instructions for the installer

2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.

This unit is equipped with a type Y fire protection, and may be set against walls that are higher than the hob.

2.1 Electrical connection

Check that the voltage and dimensioning of the supply line correspond to the characteristics shown on the plate fixed to the rear protective cover of the appliance.

This plate must never be removed.

If the appliance is hooked-up to the supply by means of a fixed connection, install a multipolar cut-out device on the line, with contact opening distance equal to or greater than 3 mm, located near the appliance and in an easily reachable position.

Hook-up to the supply may be fixed or with plug and socket. In the latter case the plug and socket must be suitable for the cable employed and conform with the regulations in force. Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

35

Image 4
Contents Contents Introduction Instructions for Safe and Proper USEPlate Must Never be Removed Electrical connection Installation of the ApplianceThis plate must never be removed Twin oven model Connecting to natural and LPG gas Ventilation requirementsAdaptation to Different Types of GAS Changing nozzlesBurner and nozzle characteristics table Arrangement of burners on cooking hobLPG G30/G31 28/37 mbar Natural GAS G20 20 mbarAdjustment of minimum for natural gas Final OperationsRegulation of minimum for LPG Positioning and levelling of the applianceDescription of Symbols Cooking HOB Burner Command KnobDescription of Controls Front control panelAuxiliary Oven Thermostat Knob Auxiliary Oven Variable Grill KnobElectronic Analogue Clock Setting the timeList of Functions Minute-minder Programming Demo Function USE of the Cooking HOB Lighting of the cooking hob burnersUSE of the Ovens Practical advice for using the cooking hob burnersDiameter of containers Available Accessories Function Switch Thermostat Selector Switch Cooking HintsHot-air cooking From 50 to 250CFunction Switch Thermostat Switch in PositionHot-air grilling Grill cookingTraditional cooking DefrostingThermostat in Position Delicate cooking Function Switch Variable Grill Choice Between MIN. and MAXVariable grill cooking Spit cooking Cleaning stainless steel Cleaning and MaintenanceCleaning of cooking hob components Cleaning the inside of the oven Self-cleaning linersUsing the self-cleaning liners Burner caps and flame cap crowns10.3.4Assembling the self-cleaning liners Looking after the self-cleaning linersDoor glass Extraordinary Maintenance Replacement of light bulbsOven door gaskets Removing the doorLubrication of gas taps