Smeg KSE912XU manual R N I N G

Page 4

W A R N I N G

Venting system MUST lead the air outside the building.

DO NOT expel the air through a ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is NOT recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A timedelay fuse or circuit breaker is recommended. The fuse must be sized per local codes in ac- cordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COP- PER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connec- tions must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the ap- pliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only for the purpose intended by the manu- facturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning the unit, switch power off at service panel and lock the service dis- connecting means to prevent power from being switched on accidentally. When the service dis- connecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

EN

 

4

 

4

Image 4
Contents KSE912XU Index Read and Save These Instructions R N I N G R N I N G Installation Recommendations and SuggestionsUSE CareDimensions ComponentsInstallation Wall drilling and bracket fixingConnections Mounting the hood bodyDucted Version AIR Exhaust System Chimney assembly Electrical ConnectionUpper exhaust chimney Lower exhaust chimneyUSE Control boardAlarm reset CleaningCare Metal grease filtersActivation of the alarm signal Charcoal filter ductless versionLighting Substitution of the filter