Smeg KSE912XU manual Mounting the hood body, Connections, Ducted Version AIR Exhaust System

Page 9

Mounting the hood body

Vr

• Before attaching the hood body, tighten the two screws Vr lo-

 

cated on the hood body mounting points.

 

• Hook the hood body onto the screws 12a.

 

• Fully tighten support screws 12a.

 

• Adjust screws Vr to level the hood body.

12a

 

Note: The Hood body should be secured to wall studs. If neces- sary, install a wood support behind the dry wall, flush mounted between 2 studs. This will provide the necessary structure and support for mounting.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using a rigid 6” duct.

Install the damper 10 ø 6”.

10

Fix the duct in position using sufficient pipe clamps (not sup-

 

plied).

DUCTLESS VERSION AIR OUTLET

15

14.1

Push fit connection 15 onto the hood body outlet.

Insert the connection extension pieces laterally 14.1 in connec-

tion 15.

• Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the con- nection extension pieces 14.1 and then reassemble as described previously.

• Ensure that the activated charcoal filters have been inserted.

EN

 

9

 

9

Image 9
Contents KSE912XU Index Read and Save These Instructions R N I N G R N I N G Recommendations and Suggestions InstallationUSE CareComponents DimensionsWall drilling and bracket fixing InstallationMounting the hood body ConnectionsDucted Version AIR Exhaust System Electrical Connection Chimney assemblyUpper exhaust chimney Lower exhaust chimneyControl board USECleaning Alarm resetCare Metal grease filtersCharcoal filter ductless version Activation of the alarm signalLighting Substitution of the filter