Smeg AS28I96L manual Adapting to Different Types of GAS, Removing the top

Page 8

Instructions for the installer

3. ADAPTING TO DIFFERENT TYPES OF GAS

Before any intervention, disconnect the power supply of the device.

The cooking hob is inspection-tested for use with G20 (2H) natural gas at a pressure of 20 mbars. If used with other types of gas, you have to replace the nozzles and regulate the primary air to the burners. Then regulate the minimum flame on the gas taps. For nozzle replacement and burner adjustment you must raise the cooking hob as described in the following paragraph.

3.1 Removing the top

1.Slide out the grids, and remove all burner caps, flame cap crowns and burners.

2.Remove the screws and nuts A which hold burner supports in place.

3.Remove plates B.

4.Lift up top C with the aid of a screwdriver and remove it from its seat.

5.Replace the burner nozzles according to the specifications in the reference gas table.

6.Adjust primary air as described in paragraph “3.2 Regulation for LPG”.

25

Image 8
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Positioning Instructions for the installerInstallation of the Appliance Electrical connection Ventilation of rooms Discharge of combustion productsGas connection Connection to LPGAdapting to Different Types of GAS Removing the topRegulation for LPG Regulation for natural gas Regulation of primary air Referred to distance X in mmAdjustment of minimum for natural gas Final OperationsRegulation of minimum for LPG Arrangement of burners on cooking hobInstructions for the user USE of the Cooking HOBBurner knob Lighting the burnersPractical advice for using the burners Diameter of containersCleaning of cooking hob components Cleaning and MaintenanceCleaning stainless steel