Sub-Zero PRO VENTILATION HOODS Heat Sentry F E AT U R E, G H T C O N T Ro L, Filter R E M O VA L

Page 11

W O L F PRO VENTILATION HOOD U S E & C A R E

R E C E S S E D CONTROLS

HEAT SENTRY F E AT U R E

Controls for Pro ventilation hoods and hood

Heat Sentry feature turns the ventilation hood

liners are recessed under the front edge of the

on when heat is sensed and adjusts the blower

hood. Refer to the illustration below.

speed automatically. The Heat Sentry feature is

 

activated when the exhaust temperature from

L I G H T C O N T RO L

the hood reaches 200˚F (95˚C) and deactivated

when the exhaust temperature decreases to

 

The left rotary switch operates the halogen

186˚F (85˚C).

lights. There are two settings, HIGH and LOW.

At 200˚F (95˚C) the blower motor will automati-

The LOW setting can be used as a night-light.

cally adjust to HIGH speed. When the sensor

From the OFF position, turn the switch to the

cools down to 186˚F (85˚C) it adjusts the blower

desired light setting, left for LOW and right for

back to the setting that is set on the blower

HIGH light setting.

control. For example, if blower motor is in LOW

 

 

speed and threshold temperature is reached,

H E AT L A M P C O N T RO L

the blower will increase to HIGH speed.

If your hood is equipped with heat lamps, a

 

center rotary switch will control the lamps.

FILTER R E M O VA L

Each heat lamp may function independently or

To remove the stainless steel filters, push each

both lamps may be activated simultaneously

from the single switch. From the OFF position,

filter up at the angle it is placed in, and rotate

simply turn the switch to the right to activate

down. Remove the center filter first. Take out

the right heat lamp or to the left to activate the

the grease cups (if applicable) placed on the

left lamp. When the switch is in the vertical

bottom edge of the hood coinciding with the

position, both heat lamps will be activated.

bottom edge of the filters. Gloves should be

 

worn to provide the proper grip. Reinstall using

B L O W E R C O N T RO L

the reverse procedure as shown in the illustra-

tion below. Outer filters may need to be pushed

 

The right rotary switch that operates the

over while the center filter is reinstalled.

blower is variable, allowing infinite control of

IMPORTANT NOTE: DO NOT operate the

the blower speed. Rotate the switch fully

ventilation hood without the filters. This may

counterclockwise to turn the blower off.

cause damage to the blower or other internal

 

 

components of the hood.

 

 

Blower

 

Heat Lamps

Control

Halogen

Control

 

 

 

Lights Control

 

Recessed controls

 

Spring

 

Filter

Grease Cup

SIDE VIEW

Filter reinstallation

11

Image 11
Contents USE & Care Information N T E N T S N TA C T F O R M AT I O N Wolf Customer Service Website Wolfappliance.comT R O D U C I N G Wolf PRO Ventilation Hoods Thank YOU F E T Y I N S T R U C T I O N S a N D P R E C a U T I O N S To Reduce the Risk of a Cooktop Grease Fire Model W482210R shown L F PRO Ventilation Hood F E AT U R E SPRO LOW- Profile Wall H O O D S W- P RO F I L E WA L L H O O DModel W482418R shown L F R R a N T YModel W482718R shown PRO 27 686 Deep Wall H O O D SModel I543418R shown PRO Island H O O D SL a N D H O O D L F WA R R a N T YModel L462212 shown RO H O O D L I N E RFilter R E M O VA L Heat Sentry F E AT U R EG H T C O N T RO L AT L a M P C O N T RO LHeat L a M P S Cleaning a N D CareG N AT U R E P O L I S H N E R a L C L E a N I N GLT E R C a R E Troubleshooting G U I D EL F PRO Ventilation Hood U S E & C a R E RO D U C T R E G I S T R AT I O N L F S E RV I C E I N F O R M AT I O NF O R E C a L L I N G F O R S E RV I C E Full TWO Year Warranty 9 3 4 0 0