Traulsen RET232EUT, RET232NUT Replacing the Gaskets, Cleaning the Exterior, Cleaning the Interior

Page 6

V. CARE & MAINTENANCE (continued)

VI. OTHER

V. c - REPLACING THE GASKETS:

To remove the gasket to be replaced, grasp it firm- ly by one corner and pull it out. Before attempting to in- stall a new gasket, both the unit and the gasket itself must be at room temperature. Insert the four corners first by using a rubber mallet (or hammer with a block of wood). After the corners are properly inserted, work your way towards the center from both ends by gently hit- ting with a mallet until the gasket is completely seated in place (see figure below for proper gasket placement).

NOTE: The gasket may appear too large, but if it is in- stalled as indicated above it will slip into place.

V. d - CLEANING THE EXTERIOR:

Exterior stainless steel should be cleaned with warm water, mild soap and a soft cloth. Apply with a dampened cloth and wipe in the direction of the metal grain.

Avoid the use of strong detergents and gritty, abrasive cleaners as they may tend to mar and scratch the surface. Do NOT use cleansers containing chlorine, this may pro- mote corrosion of the stainless steel.

Care should also be taken to avoid splashing the unit with water, containing chlorinated cleansers, whenmopping the floor around the unit.

For stubborn odor spills, use baking soda and water (mixed to a 1 TBSP baking soda to 1 pint water ratio).

V. e - CLEANING THE INTERIOR:

For cleaning both stainless steel and anodized aluminum interiors, the use of baking soda as described in section “V. d” is recommended. Use on breaker strips as well as door gaskets. All interior fittings are removable without tools to facilitate cleaning.

VI. a - SERVICE INFORMATION:

Before calling for service, please check the following:

Is the electrical cord plugged in?

Is the fuse OK or circuit breaker on?

Is the power switch “ON”?

If after checking the above items and the unit is still not oper- ating properly, please contact an authorized Traulsen service agent. A complete list of authorized service agents was provided along with your Traulsen unit. If you cannot locate this, you may also obtain the name of a service agent from the Service/Contact page of our website: www.traulsen.com.

If service is not satisfactory, please contact our in-house service department at:

Traulsen

4401 Blue Mound Road Fort Worth, TX 76106 (800) 825-8220

Traulsen reserves the right to change specifications or dis- continue models without notice.

VI. b - SPARE PARTS:

Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents. A complete list of authorized service agents accompanies this manual and is also posted on our company’s official website @ www.traulsen.com.

VI. c - WARRANTY REGISTRATION:

For your convenience, the warranties on your new Traulsen unit may be registered with us on-line at

www.traulsen.com, or by completing and return- ing the warranty card included along with the unit.

To do so on-line, from the menu at the top right of the home page, select CONTACT US/DEALER DIRECTORY. Upon loading that page, select WARRANTY REGISTRATION from the menu. A link to the WARRANTY REGISTRATION form should appear. Complete the required information, and hit the SUBMIT button when finished.

-5-

Image 6
Contents RET132EUT RET232EUT RET232NUT Table of Contents Serial TAGII. Receipt Inspection III. InstallationIII. c Installing Legs or Casters III. a LocationIII. d Tray Slides III. f Power SupplyIII. g Wiring Diagram III. e Cord & PlugHinge Replacement IV. g Adjusting the Temperature ScaleCleaning the Condenser IV. d Batch LoadingVI. a Service Information Cleaning the ExteriorCleaning the Interior VI. b Spare Parts VI. c Warranty RegistrationVII. General USE, Operation Service Summary VIII. e Incomplete Thawing VIII. Expected Thaw PERFORMANCE/OPERATIONAL TroubleshootingVIII. f Equipment Issues Reduced AIR Movement Equates to Longer Thawing TimesIX. Trouble Shooting Guide Find Your Problem Here RemedyRE232E-FHS Spare Parts ListModel Description Part Number RE132E-FHS RE232N-FHSXI. Wiring Diagram ALL ONE Section Models only XI. Wiring Diagram Models RET232NUT-FHS & RET232NUT-HHS only XI. Wiring Diagram Models RET232EUT-FHS & RET232EUT-HHS only XII. Warranty Information Standard Domestic WarrantyPage Hours of Operation

RET132EUT, RET232NUT, RET232EUT specifications

The Traulsen RET232EUT, RET232NUT, and RET132EUT are commercial refrigerators designed to meet the rigorous demands of the food service industry. Renowned for their reliability, efficiency, and innovative features, these models ensure that perishable goods are stored safely and at the optimal temperature.

One of the standout features of the Traulsen RET232EUT and RET232NUT is their energy efficiency. These refrigerators are equipped with high-performance, energy-saving compressors that reduce electricity consumption while maintaining precise temperature control. This not only lowers operational costs but also minimizes the environmental impact of refrigeration. The self-contained refrigeration system allows for easy access and maintenance, making them user-friendly for busy kitchen environments.

The Traulsen RET132EUT, on the other hand, is designed with a specific focus on maximizing storage capacity within a compact footprint. With its durable stainless steel exterior and aluminum interior, it is built to withstand the rigors of daily use while ensuring longevity. This model features adjustable, heavy-duty shelves that provide flexibility in organizing products, accommodating various sizes and shapes of food items.

All models feature digital temperature controls, which allow for accurate monitoring and adjustments. This advanced technology ensures that the inside temperature stays within the desired range, protecting food quality and safety. The easy-to-read LED display offers clear visibility of the internal temperature, enhancing usability in fast-paced kitchen settings.

The RET232EUT and RET132EUT models also boast a unique air distribution system that guarantees even cooling throughout the cabinet. This design feature is crucial in preventing temperature fluctuations that could compromise food safety. Additionally, the interior is equipped with an easily accessible drainage system that simplifies cleaning and sanitation procedures.

Safety features, such as door locks and integrated alarms, are also present in these models. These elements ensure that food is not only stored at optimal temperatures but also protected from unauthorized access.

In summary, the Traulsen RET232EUT, RET232NUT, and RET132EUT models exemplify quality and innovation in commercial refrigeration. Their combination of energy efficiency, robust design, advanced temperature control, and user-friendly features make them an ideal choice for restaurants, catering services, and other food service operations, ensuring food safety and reliability in kitchen environments.