AEG S 75400 KG8, 200372733 manual If something does not work, Problem Possible cause Solution

Page 25

If something does not work

During operation of the appliance some smaller but annoying trouble can often occur, which does not require calling a technician out. In the following chart information is given about them to avoid unnecessary charges on serv- ice.

We draw your attention that operation of appliance goes with certain sounds (compressor- and circulating sound). This does not necessarily mean a fault has occurred, this goes together with the operation of the appliance.

We draw it to your attention again that the appliance operates discontinu- ously, so the stopping of compressor does not mean being no-current. That is why you must not touch the electrical parts of the appliance before break- ing the circuit.

 

 

 

Problem

Possible cause

Solution

It is too warm in the

Thermostatic control can be set incor-

Set the thermostat knob to higher

refrigerator.

rectly.

position.

 

If products are not cold enough or

Place the products according to the

 

placed incorrectly.

chapter „Storing in the refrigerator”.

 

The door does not close tightly or it is

Check if the door closes well and the

 

not shut properly.

gasket is unhurt and clean.

It is too warm in the

Thermostatic control can be set incor-

Set the thermostat knob to higher

rectly.

position.

freezer.

 

 

 

The door does not close tightly or it is

Check if the door closes well and the

 

not shut properly.

gasket is unhurt and clean.

 

Products in big quantity to be frozen

Wait some hours and then check the

 

were put in.

temperature again.

 

Products to be frozen are placed too

Place the products in a way so that

 

closely to each other.

cold air could circulate among them.

Water flows at the

It is normal. During automatic defrost-

 

ing frost melts on the back plate.

 

back plate in the

 

 

 

refrigerator.

The outlet of the chamber can be

Clean the outlet.

Water flows into the

clogged up.

 

 

 

chamber.

Products placed in can prevent water

Replace the products so that they can

 

from flowing into the collector.

 

not touch the back plate directly.

 

 

Water flows onto the

The melting water outlet flows not

Put the melting water outlet to the

into the evaporative tray above the

floor.

evaporative tray.

compressor.

 

 

There are too much

Products are not wrapped properly.

Wrap the products better.

frost and ice.

Doors are not shut properly or do not

Check if the doors close well and the

 

close tightly.

gaskets are unhurt and clean.

 

The thermostatic control can be set

Set the thermostat knob to a position

 

incorrectly.

that gives higher temperature.

 

 

 

25

Image 25
Contents 75400 KG 75400 KG8 Dear customer Contents Some useful information and advice General safety precautions Important safety informationSafety precautions for installation Precautions for child safetySafety precautions for isobutane Cleaning Installing the applianceTransportation, unpacking Class of climate Ambient temperature PlacementInstallation of the Carbon Filter Door reversal Page Temperature setting buttons Operating and indicator panel FridgeTemperature display Holiday function Starting Up Setting the TemperatureInterior Accessories How to use the refrigeratorStorage Shelves Drawer Air FilterChiller Zone Storing in the refrigeratorOperating and indicator panel Freezer Frostmatic Alarm reset buttonFreezing and storing frozen food Switching the Appliance offStoring in the freezer Some useful information and advice Hints and ideas How to save energyAppliance and environment Regular cleaning MaintenanceInternal cleaning External cleaningFrom the surface Changing the Carbon FilterIf something does not work Problem Possible cause SolutionThermostatic control is set incor Electrical connection How to change the bulbElectrical Requirements Page AE/7-2 Page 2009