If something does not work
During operation of the appliance some smaller but annoying trouble can often occur, which does not require calling a technician out. In the following chart information is given about them to avoid unnecessary charges on serv- ice.
We draw your attention that operation of appliance goes with certain sounds (compressor- and circulating sound). This does not necessarily mean a fault has occurred, this goes together with the operation of the appliance.
We draw it to your attention again that the appliance operates discontinu- ously, so the stopping of compressor does not mean being
|
|
| |
Problem | Possible cause | Solution | |
It is too warm in the | Thermostatic control can be set incor- | Set the thermostat knob to higher | |
refrigerator. | rectly. | position. | |
| If products are not cold enough or | Place the products according to the | |
| placed incorrectly. | chapter „Storing in the refrigerator”. | |
| The door does not close tightly or it is | Check if the door closes well and the | |
| not shut properly. | gasket is unhurt and clean. | |
It is too warm in the | Thermostatic control can be set incor- | Set the thermostat knob to higher | |
rectly. | position. | ||
freezer. | |||
|
| ||
| The door does not close tightly or it is | Check if the door closes well and the | |
| not shut properly. | gasket is unhurt and clean. | |
| Products in big quantity to be frozen | Wait some hours and then check the | |
| were put in. | temperature again. | |
| Products to be frozen are placed too | Place the products in a way so that | |
| closely to each other. | cold air could circulate among them. | |
Water flows at the | It is normal. During automatic defrost- |
| |
ing frost melts on the back plate. |
| ||
back plate in the |
| ||
|
| ||
refrigerator. | The outlet of the chamber can be | Clean the outlet. | |
Water flows into the | clogged up. |
| |
|
| ||
chamber. | Products placed in can prevent water | Replace the products so that they can | |
| from flowing into the collector. | ||
| not touch the back plate directly. | ||
|
| ||
Water flows onto the | The melting water outlet flows not | Put the melting water outlet to the | |
into the evaporative tray above the | |||
floor. | evaporative tray. | ||
compressor. | |||
|
| ||
There are too much | Products are not wrapped properly. | Wrap the products better. | |
frost and ice. | Doors are not shut properly or do not | Check if the doors close well and the | |
| close tightly. | gaskets are unhurt and clean. | |
| The thermostatic control can be set | Set the thermostat knob to a position | |
| incorrectly. | that gives higher temperature. | |
|
|
|