Cornelius R-134A manual Recognize Safety Information

Page 4

SAFETY INFORMATION

Recognize Safety Information

This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the possibility of personal injury.

Follow recommended precautions and safe operating practices.

Understand Signal Words

A signal word - DANGER, WARNING, OR CAUTION is used with the safety-alert symbol. DANGER identi- fies the most serious hazards.

Safety signs with signal word DANGER or WARNING are typically near specific hazards.

General precautions are listed on CAUTION safety signs. CAUTION also calls attention to safety mes- sages in this manual.

DANGER

WARNING

CAUTION

Follow Safety Instructions

Carefully read all safety messages in this manual and on your machine safety signs. Keep safety signs in good condition. Replace missing or damaged safety signs. Learn how to operate the machine and how to use the controls properly. Do not let anyone operate the machine without instructions. Keep your machine in proper working condition. Unauthorized modifications to the machine may impair function, safety, and affect the machine life and may void the factory warranty.

CO2 (Carbon Dioxide) Warning

CO2 Displaces Oxygen. Strict Attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Person- nel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.

Shipping, Storing, Or Relocating Unit

CAUTION: All water must be purged from the Unit if exposed to freezing temperature. A freezing am- bient temperature will cause residual water remaining inside the Unit to freeze resulting in damage to internal components of the Unit.

1

312021002

Image 4
Contents Sentry III-A POST-MIX Cooling Unit This Document Contains Important InformationTable of Contents Table of Contents cont’d Safety Information Recognize Safety InformationThis page Left Blank Intentionally Warranty Reference Information General InformationClaims Instructions Design DataDROP--IN Refrigeration Assembly Data DescriptionTheory of Operation Sentry III-A Cooling UnitSystem Flow Diagram Carbonator Water Pump Motor Safety Thermostat Parts Identification312021002 OWNER’S Recommended Maintenance Maintenance ScheduleThis page Left Blank Intentionally Operating Controls Operators InstructionsDaily PRE-OPERATION Check This page Left Blank Intentionally General Maintenance AdjustmentsContent Water Where a Local Water Problem Exist Sanitizing Syrup SystemsCleaning Condenser Coil Replenishing CO2 SupplyPeriodic Cleaning of Cooling Unit Cleaning and SanitizingReplenishing Syrup Supply Wash Syrup SystemsFlush Syrup Systems Sanitize Syrup SystemsPurge Water OUT of Syrup Systems Restore Operation Water Flush Syrup Systems312021002 Troubleshooting TOO LOW.CONT’D Compressor does notCompressor Operates Continuously but doesWarranty Page One Cornelius Place Anoka, Minnesota 612 800
Related manuals
Manual 54 pages 24.45 Kb

R-134A specifications

Cornelius R-134A is a refrigerant commonly used in various cooling and air conditioning applications. It belongs to the hydrofluorocarbon (HFC) family and has become a favored alternative to many ozone-depleting substances. Unlike its predecessors, R-12, which has been phased out due to its detrimental effects on the ozone layer, R-134A offers a more environmentally friendly solution, albeit still having global warming potential.

One of the main features of R-134A is its favorable thermodynamic properties. It exhibits a low boiling point of approximately -26.3°C (-15.3°F), making it suitable for various refrigeration applications, including automotive air conditioning, commercial cooling systems, and domestic refrigerators. Its efficiency is regarded as superior, allowing for quick heat absorption and dissipation. This efficiency translates into energy savings, ultimately benefiting both consumers and manufacturers.

R-134A also boasts a relatively high vaporization heat, demonstrating its effectiveness in heat transfer processes. The low toxicity and non-flammability of R-134A further enhance its appeal, as it poses minimal risk during handling and application. This characteristic makes R-134A safer for technicians and users compared to older refrigerants, which presented higher health hazards.

Within modern technologies, R-134A plays a crucial role in both chiller systems and heat pump applications. It is compatible with various lubricants, allowing manufacturers to utilize R-134A in existing systems with minimal modifications. However, it is essential to use the correct type of oil, as mixing different types can lead to system inefficiencies and potential failure.

Despite its advantages, R-134A has a global warming potential of around 1,430 times greater than carbon dioxide, prompting the refrigerant industry to look for alternatives. Newer refrigerants, such as R-1234yf, offer lower environmental impact, driving a shift towards more sustainable options.

In conclusion, Cornelius R-134A remains a widely used refrigerant known for its efficiency, safety, and effectiveness in heat transfer. While it has played a significant role in the refrigeration and air conditioning industries, the ongoing search for eco-friendly alternatives highlights the need for continued innovation and adherence to environmental standards.