Cornelius R-134A manual Theory of Operation, Sentry III-A Cooling Unit

Page 8

FIGURE 1. SENTRY III-A COOLING UNIT

THEORY OF OPERATION

(see Figure 2)

A CO2 cylinder delivers carbon dioxide gas (CO2) through adjustable CO2 regulators to the soft drink tanks and also to the built--in carbonator located inside the Cooling Unit. Plain water is pumped into the carbonated water tank by the water pump and is carbonated by regulated CO2 pressure also entering the tank. When dispensing valve is opened, CO2 pressure exerted upon the syrup in the soft drink tank pushes syrup from the tank, through the Cooling Unit cooling coils, through the python and on to the dispensing valve. Carbonated water is pushed by CO2 pressure from the carbonated water tank, through the Cooling Unit cooling coils, through the python and on to the dispensing valve. Syrup and carbonated water meet at the dispensing valve resulting in a carbonated drink being dispensed. Plain water is also available at the dispensing station by passing through the Cooling Unit cooling coils, through the python, and on to the dispensing station. Carbonated water is replen- ished when carbonated water level inside the carbonator tank drops to a specified level which in turn automati- cally starts the carbonator water pump motor. When carbonated water level inside the carbonated water tank has been replenished, carbonator water pump motor will stop. Carbonated water is continuously being circu- lated from the Cooling Unit, out through the insulated python to the dispensing station(s), and back to the cool- ing unit which maintains liquids in the python at a cold temperature.

5

312021002

 

Image 8
Contents Sentry III-A POST-MIX Cooling Unit This Document Contains Important InformationTable of Contents Table of Contents cont’d Safety Information Recognize Safety InformationThis page Left Blank Intentionally Warranty Reference Information General InformationClaims Instructions Design DataDROP--IN Refrigeration Assembly Data DescriptionTheory of Operation Sentry III-A Cooling UnitSystem Flow Diagram Carbonator Water Pump Motor Safety Thermostat Parts Identification312021002 OWNER’S Recommended Maintenance Maintenance ScheduleThis page Left Blank Intentionally Daily PRE-OPERATION Check Operators InstructionsOperating Controls This page Left Blank Intentionally General Maintenance AdjustmentsContent Water Where a Local Water Problem Exist Sanitizing Syrup SystemsCleaning Condenser Coil Replenishing CO2 SupplyPeriodic Cleaning of Cooling Unit Cleaning and SanitizingReplenishing Syrup Supply Wash Syrup SystemsFlush Syrup Systems Sanitize Syrup SystemsPurge Water OUT of Syrup Systems Restore Operation Water Flush Syrup Systems312021002 Troubleshooting TOO LOW.CONT’D Compressor does notCompressor Operates Continuously but doesWarranty Page One Cornelius Place Anoka, Minnesota 612 800
Related manuals
Manual 54 pages 24.45 Kb

R-134A specifications

Cornelius R-134A is a refrigerant commonly used in various cooling and air conditioning applications. It belongs to the hydrofluorocarbon (HFC) family and has become a favored alternative to many ozone-depleting substances. Unlike its predecessors, R-12, which has been phased out due to its detrimental effects on the ozone layer, R-134A offers a more environmentally friendly solution, albeit still having global warming potential.

One of the main features of R-134A is its favorable thermodynamic properties. It exhibits a low boiling point of approximately -26.3°C (-15.3°F), making it suitable for various refrigeration applications, including automotive air conditioning, commercial cooling systems, and domestic refrigerators. Its efficiency is regarded as superior, allowing for quick heat absorption and dissipation. This efficiency translates into energy savings, ultimately benefiting both consumers and manufacturers.

R-134A also boasts a relatively high vaporization heat, demonstrating its effectiveness in heat transfer processes. The low toxicity and non-flammability of R-134A further enhance its appeal, as it poses minimal risk during handling and application. This characteristic makes R-134A safer for technicians and users compared to older refrigerants, which presented higher health hazards.

Within modern technologies, R-134A plays a crucial role in both chiller systems and heat pump applications. It is compatible with various lubricants, allowing manufacturers to utilize R-134A in existing systems with minimal modifications. However, it is essential to use the correct type of oil, as mixing different types can lead to system inefficiencies and potential failure.

Despite its advantages, R-134A has a global warming potential of around 1,430 times greater than carbon dioxide, prompting the refrigerant industry to look for alternatives. Newer refrigerants, such as R-1234yf, offer lower environmental impact, driving a shift towards more sustainable options.

In conclusion, Cornelius R-134A remains a widely used refrigerant known for its efficiency, safety, and effectiveness in heat transfer. While it has played a significant role in the refrigeration and air conditioning industries, the ongoing search for eco-friendly alternatives highlights the need for continued innovation and adherence to environmental standards.