PROBLEMPOSSIBLE CAUSE
Burner | Burner ports are clogged. |
flames | are |
uneven |
|
SOLUTION
Clean with a straight pin (see pages 19 and 23). If this fails, call an authorized Roper service technician for service.
Burner
flames lift off ports, are yellow, or are noisy when turned
Off
Burner makes popping noise when on
Control knob(s) will not turn
Cooking results are not what you expected
Air/gas mixture is incorrect.
Burner is wet from washing.
You are not pushing in before turning.
The range is not level.
The oven temperature seems too low or too high.
The oven was not preheated as the recipe calls for.
The recipe has never been tested or is not from a reliable source.
The pans are not the type or size recommended in the recipe.
There is not proper air circula- tion around pan when baking.
Flame size does not fit the cooking utensil being used.
When broiling, you have not completely closed the broiler drawer.
Contact an authorized Roper service technician to check air/gas mixture.
Let dry.
Push control knob(s) in before turning to a setting.
Level range. (See Installation Instructions.)
Adjust the oven temperature control. (See “Adjusting the oven temperature control” on page 13.)
Preheat oven if called for in recipe.
Use only tested recipes from a reliable source.
Refer to a reliable cookbook for recommended pan type and size.
Allow 1l/2 to 2 inches
Adjust flame size to fit cooking utensil.
Completely close broiler drawer.
26