INSTALLATION

CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES.

NOTE: Water pipe connections and fixtures directly connected to the potable water supply must be sized, installed, and maintained in accordance with NSF Standard 18, as well as Federal, State, and Local codes.

NOTE: It is the installer’s responsibility to ensure that the water supply is equipped with protec- tion against backflow. This protection can be an air gap as defined by ANSI/ASME A112.1.2-1979, or by an approved vacuum breaker or other approved method.

INSTALLATION REQUIREMENTS

Requirements Summary

Weight:

front or rear counter must be level and able to support 400 lbs.

Environment:

indoor installation only

Temperature:

40 to 110° F ambient temperature

Clearance:

18-inches above

6-inches on sides and rear

CO2:

75 psi (5.25 bar) at unit with internal carbonator

Concentrate:

60 psi

Water:

50 psi maximum

Electrical:

see nameplate on unit for electrical requirements

Electrical Requirements

Before connecting electrical power to the unit refer to nameplate to verify power requirements.

DANGER — To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must be installed in electrical circuit of all 50 Hz units.

WARNING — To avoid possible electrical shock the unit must be electrically grounded using the green grounding screw provided inside the electrical contractor box.

CAUTION — The wiring must be properly grounded and connected through a 10-amp disconnect switch (slow–blow fuse or equivalent HVAC/R circuit breaker). ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. MAKE SURE UNIT IS PROP-

ERLY GROUNDED.

Publication Number: 859000159INS

- 2 -

© 2003, IMI Cornelius Inc.

Image 6
Contents Impulse Contact Information Table of Contents Publication Number 859000159INS 2003, IMI Cornelius Inc Safety System DimensionsInstallation Requirements SummaryElectrical Requirements Counter-top Installation Global ICE Bank Control Gibo Theory of OperationAdjust Water-To-Concentrate Ratio Connect Concentrate and Water LinesAdjusting Flow Rates Starting And Stopping the Unit Water-to-Concentrate Ratio AdjustmentOperations Dispensing ProductSanitizing Concentrate Systems Daily CleaningDaily Checks Wash Concentrate SystemsPurge Water out of Concentrate Systems Restore Operation Sanitize Concentrate SystemsWater Flush Concentrate Systems Wiring Diagram Reference MaterialInternal Carbonator External CarbonatorNon-Carbonated Impulse Installation & Operations Manual Troubleshooting WATER-TO-CONCENTRATE Ratiotoo LOW or TOO HighTroubleshooting Refrigeration System OperatePublication Number 859000159INS 2003, IMI Cornelius Inc Page IMI Cornelius Inc One Cornelius Place Anoka, MN

Non-Carbonated Post-Mix Beverage Dispenser specifications

The Cornelius Non-Carbonated Post-Mix Beverage Dispenser is a revolutionary solution for beverage service, designed to meet the diverse needs of restaurants, cafes, and convenience stores. Renowned for its user-friendly operation and efficient performance, this dispenser stands out in the competitive landscape of beverage dispensing technology.

One of the main features of the Cornelius Non-Carbonated Post-Mix Beverage Dispenser is its ability to serve a variety of non-carbonated drinks, including fruit juices, iced teas, and flavored waters. This versatility makes it suitable for establishments looking to expand their beverage offerings while ensuring quality and consistency. With multiple flavor options, operators can easily customize the drink menu to cater to customer preferences.

The design of the Cornelius dispenser incorporates state-of-the-art technologies that enhance its functionality and reliability. It features a high-efficiency refrigeration system that maintains optimal serving temperatures, ensuring beverages are always fresh and refreshing. The user-friendly interface, complete with an intuitive digital display, allows staff to quickly and accurately select drink options, minimizing wait times for customers.

In terms of operational benefits, the Cornelius Non-Carbonated Post-Mix Dispenser is designed for easy maintenance. Its modular construction allows for rapid component access, reducing downtime during service. The cleaning process is streamlined, facilitating hygiene and compliance with food safety regulations.

Another noteworthy characteristic of this beverage dispenser is its eco-friendly approach. By utilizing a post-mix configuration, it reduces the need for individual packaging, which contributes to lowering environmental impact. This is an important consideration for businesses aiming to adopt sustainable practices.

Moreover, the dispenser’s energy-efficient design plays a crucial role in reducing operational costs. By consuming less power while maintaining peak performance, it enables establishments to manage their operating expenses effectively without sacrificing service quality.

Overall, the Cornelius Non-Carbonated Post-Mix Beverage Dispenser is an exceptional choice for those seeking to enhance their beverage service. With its robust features, advanced technology, and a commitment to sustainability, it provides a competitive edge in today’s fast-paced food and beverage industry. Investing in this advanced dispenser ensures businesses can deliver high-quality, customizable beverages that delight customers and drive sales.