IDC Operator’s Manual
Replenishing CO2 Supply
NOTE: When indicator on the
1.Fully close (clockwise) the CO2 cylinder valve.
2.Slowly loosen the CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove the regulator assembly from the empty CO2 cylinder.
3.Unfasten safety chain and remove the empty CO2 cylinder.
WARNING: To avoid personnel injury and/or property damage, always secure the CO2 cylinder with a safety chain to prevent it from falling over. Should the valve become accidently damaged or broken off, a CO2 regulator can cause serious personnel injury.
4.Position the full CO2 cylinder and secure with a safety chain.
5.Make sure gasket is in place inside the CO2 regulator assembly coupling nut, then install the regulator assembly on the CO2 cylinder.
6.Open (counterclockwise) the CO2 cylinder valve slightly to allow the lines to slowly fill with gas, then open the valve fully to
7.Check CO2 connections for leaks. Tighten any loose connections.
Cleaning Dispensing Valve
1.Remove nozzle assembly (contains Inner Nozzle) from dispensing valve. Separate the inner nozzle from the nozzle and wash the two parts in warm water.
2.Remove the bottom plate by releasing the two
3.Reassemble the lever into the bottom plate and return the bottom plate to the valve. Be sure the rear tabs are properly secured.
4.Return the inner nozzle to the nozzle and replace the assembly to the valve.
| BOTTOM | |
SNAP FIT CLIP | PLATE P/N | |
1903 | ||
| ||
| SNAP FIT | |
| CLIP |
SNAP FIT |
| REAR | |
CLIP |
| ||
O | TAB | ||
| |||
|
|
FSNAP FIT
FCLIP
INNER
NOZZLE
NOZZLE
© | - 5 - | Publication Number: 621057403OPR |