Cornelius IMD Series installation manual Auger & Extruding Head Removal, Upper NUT and Bearings

Page 17

Countertop Icemaker IMD Series Installation Manual

AUGER & EXTRUDING HEAD REMOVAL

1.Disconnect unit from power supply.

2.Remove storage container cover and put aside.

3.Turn off water supply to icemaker.

4.After ice has melted from head take hold of the auger nut and lift straight up to disengage from ice- maker.

5.When replacing the auger assembly, make certain that both the auger engages the output shaft drive and the extruding head ribs engage the evaporator tube collar. See FIGURE 8.

FIGURE 9. IMD 600 SHAFT SEAL

INSTALLATION AND SHAFT SEAL REPLACEMENT (FIGURE 9)

1.Place shaft seal locator seat over gear motor output shaft, embossed side down, and push down until shaft seal seat rests flush on top of gear motor.

2.Place rubber coated ceramic seal (important: ceramic face up) over output shaft and push down until seal rests on top of the shaft seal seat. (Lubricate rubber on ceramic seal with [#06195] rubber lubricant.)

3.Place shaft seal with carbon face down (spring up) over output shaft and push (gently) downward until seal rests on carbon face of the output shaft seal.

4.Place flat washer over output shaft and let rest on the output shaft seal. Push down on the washer compressing the spring on the output shaft seal. While holding the seals (down) in place slide the E-ring into the groove on the output shaft.

UPPER NUT AND BEARINGS

The upper bearings located on top of the auger is used to absorb the force between the auger and extruding head.

The bearings are 3/32” thick. When they wear below 1/16” they should be replaced. Bearings to be inspected for wear during quarterly maintenance. See FIGURE 8.

© 2004-2009, IMI Cornelius Inc.

- 13 -

Publication Number: 638085277INS

Image 17
Contents Countertop Icemaker IMI Cornelius Inc Countertop Icemaker IMD Series Installation ManualTable of Contents Safety Controls Guide to Good Ice Safety Instructions SafetySafety Tips CO2 Carbon Dioxide Warning Shipping and StorageRLA Specification ChartDimension Drawings 30 LBS. IMD 300-30 and IMD Installation Instructions Auger Engagement Initial Start UP, Checks & Adjustment InstructionsDrain Connection Publication Number 638085277INS 2004-2009, IMI Cornelius Inc Icemaker Cleaning and Sanitizing Procedures Guide to ServiceMaintenance MonthlySEMI-ANNUALLY Upper Bearing and Auger AssemblyWater Level Control Adjustment and Troubleshooting Refrigeration System AdjustmentsCondenser Modulating Valve Removal Condenser Modulating ValveGear Motor Shaft Seal Installation and Replacement FigureUpper NUT and Bearings Installation and Shaft Seal Replacement FigureAuger & Extruding Head Removal Electrical Checkout Troubleshooting CompressorTo Replace Bearings Capacitor Check Troubleshooting Gear MotorsCompressor Check Figure Motor Check Safety Controls Check Icemaker Location Conditions First Guide to Good ICETroubleshooting Chart Icemaker not Operating IMD-15 Wiring Diagram Countertop Icemaker IMD Series Installation Manual Schematic IMD 302-30, IMD 602-30, and IMD IMI Cornelius Inc